PDF-MANUALS.com | User manual here!
User manual

User manual American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32

Operating instructions and pdf manual for use - American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32 User manual, User manual American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32, American, Dynamics, MegaPower, LT, Matrix, Switc


User manual for American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32

American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32
  • Manufacturer: American Dynamics
  • Basic description and contents of package
  • Product classification: Surveillance - Surveillance Video - Matrix Solutions - Matrix Switches
  • Safety instructions
  • Startup and operation of the matrix switches
  • Tips for setting up your American Dynamics
  • Settings and expert assistance
  • Contact American Dynamics service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32, which address similar problems with connecting and setting up Matrix Switches American Dynamics.



User manual for the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32

The user manual for the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32 provides necessary instructions for the proper use of the product Surveillance - Surveillance Video - Matrix Solutions - Matrix Switches.

Designed to satisfy the needs of small scale installations, the American Dynamics AMMPLT32 MegaPower LT 32x8 Matrix Switcher (NTSC/PAL) offers 32 video inputs and 8 video outputs. The switcher has DirectSet function that enables you to change dome camera settings through an on-screen selection or a keyboard command; you do not need to access the dome menus for this purpose. It is a small system that can be fixed at different spots - be it on walls or under the desks - as per your convenience.

With the MegaPower LT, you can establish 16 tours of video inputs which can be run both in forward or reverse modes. The tours can include multiple presets and patterns from a single camera or a single video input multiple times. The switcher enables you to program alarm inputs to call any video input to one or multiple video outputs. At the same time, you can assign a camera, alarm title, event message, preset, keyboard sound level and/or auxiliary action for each alarm. Through the ADnet (RS-485) and RS-232 communication protocols, you can control fixed and variable-speed domes, auxiliary outputs, presets, and patterns at suitably equipped camera sites.

The MegaPower LT restricts unauthorized menu access which is passcode protected. Keeping the hierarchical issue in view, the system provides three levels of menu access - administrator, supervisor, and operator. The administrator is the only one to get access to the alarm and installer menus. In order to deal with video loss, the MegaPower LT comes forth with a "Video Loss Camera" message as soon as you select such a camera.

The global alarm settings of the MegaPower LT feature three response modes - Acknowledgement, Transparent, and Timeout. The Acknowledgement response remains active from the time an alarm is triggered until an operator clears the alarm manually. The Transparent response continues until the alarm contacts come back to the resting state or get cleared manually. The Timeout response exists until the expiration of the timeout period as specified in the menu or until it is cleared manually.

The alarm settings also feature five display modes. The display mode 'None' does not bring about any changes to the display whereas the mode 'Last' displays the last alarm received until it is cleared. The 'Stack' display mode keeps a response on the way if all the alarm monitors are full. The display mode 'Switch' shows the first triggered response on all the alarm monitors and displays the next response on all alarm monitors once the earlier one is cleared. The display option 'Rotate' switches the triggered response to all the alarm monitors. This mode displays each response in a cycling sequence in case of multiple responses.

The MegaPower LT allows you to configure each of the monitors to display alarm messages, date/time, video input numbers, monitor numbers, 16 character user-definable video inputs, and event messages. You can set the display to either a 12-hour clock or a 24-hour clock. In addition, the date can also be set in a format of your convenience as the device offers three different date formats i.e. MM/DD/YY, YY/MM/DD, and DD/MM/YY. The 'daylight savings' option enables you to adjust the clock as per the time zone or according to your preference.
If you own a American Dynamics matrix switches and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32:
Signal System NTSC/PAL
Video Inputs BNC x32 (looping)
Video Outputs BNC x8
Control Ports RS-485/RS-232
One 8-pin Modular RJ-45 jack (expandable)Optional Port Expander extends the RS-232 port to 4

SensorNet
1 port, 1 connector (16 inputs) or 2 ports, 2 connectors (32 inputs) through 5-pinpluggable Eurostyle terminal screw connectors
Control Protocol SensorNet
32 devices per port at a maximum distance of1 km (3,000 ft) on one 22 AWG unshielded twisted pair (UTP)

ADnet
16 devices at a maximum distance of 1.2 km (3,900 ft) on shielded/screened Cat5 wire or better or Belden 8761 or equivalent

AD-UTC
700 m (2,300 ft) on 20 AWG RG59/U coax (Belden 8281 or equivalent) or URM70 cable

FSK Telemetry
350 m on 20 AWG RG59/U coax — Baxall, Vista and Dennard domes (via DAX)
Alarm Inputs 4 Connectors (16 inputs) or 8 connectors, (32 inputs) through 5-pin pluggable Eurostyle terminal screw connector
Alarm Outputs 1 connector, 1 output (16 inputs) or 2 connectors, 2 outputs (32 inputs) Form-C relays through 3-pin Eurostyle terminal screw connectors
Power Requirements 12VDC (power supply included)
Power Consumption 2A
Operating Temperature 0 - 104°F (0 - 40°C)
Dimensions (WxHxD) 17.5 x 3.5 x 7.3" (445 x 90 x 185mm)
Weight 10.4 lbs (4.7kg)
Packaging Info
Package Weight 2.0 lb
Box Dimensions (LxWxH) 21.5 x 10.9 x 8.6"
The user manual for the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32 can be downloaded in .pdf format if it did not come with your new matrix switches, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other American Dynamics users keep a unique electronic library for American Dynamics matrix switchess, where you can use our link to download the user manual for the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32.

The user manual lists all of the functions of the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32, all the basic and advanced features and tells you how to use the matrix switches. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from American Dynamics service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32. User manuals are also available on the American Dynamics website under Surveillance - Surveillance Video - Matrix Solutions - Matrix Switches.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32 - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the American Dynamics MegaPower LT Matrix Switcher - 32x8 ADMPLT32

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
Posted by: Jae Gil, Ha
2024-04-25 09:48:07

needs manual file...
Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
Posted by: Judy Whiteley
2024-04-24 16:51:27

Please send user’s manual in normal size print...
Need manual - Sunpak Universal SelfieWand for Smartphones, Point SP-BSW-BK
Posted by: Sam
2024-04-23 19:26:40

Please send...
Yongnuo YN467 Manual - Yongnuo YN-460II Flash Speedlite YN-460II
Posted by: Robert
2024-04-21 16:35:48

Please may I have a PDF copy of the manual? Thank you....
hk EA600 amp - HK AUDIO EA600 600W Class-D Power Amplifier EA600
Posted by: Ky Trinh
2024-04-20 09:31:19

Can you directly connect the ea600 amp to the E110A active subwoofer?...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx