APC  Back-UPS Connect BGE50ML
  • Manufacturer: APC
  • Basic description and contents of package
  • Product classification: Computers & Solutions - Power - UPS Backup
  • Safety instructions
  • Startup and operation of the ups backup
  • Tips for setting up your APC
  • Settings and expert assistance
  • Contact APC service
  • Troubleshooting
  • Warranty information
  • Price: 110 USD
We recommend checking out our discussion threads on the APC Back-UPS Connect BGE50ML, which address similar problems with connecting and setting up UPS Backup APC.



User manual for the APC Back-UPS Connect BGE50ML

The user manual for the APC Back-UPS Connect BGE50ML provides necessary instructions for the proper use of the product Computers & Solutions - Power - UPS Backup.

Provide up to two hours of power to your network during power outages, allowing you to remain connected to the Internet using the Back-UPS Connect from APC. The Back-UPS Connect is powered by a removable lithium-ion mobile power pack, which is also able to charge your mobile devices while on the go. This mobile power pack recharges in as quickly as 2.5 hours and has 3 x USB ports, including 2 x 1A ports and a 1 x 2.4A smart charging port that can charge a smartphone up to five times before needing to be recharged.

This power supply also features an output of 50W / 84 VA, an input of 120V with 50/60 Hz auto-sensing technology, a NEMA 5-15P input connection, and 2 x NEMA 5-15R output connections. It is also built with a 340J surge energy rating and an LED status display.

The Back-UPS Connect is well-suited for devices such as wireless routers, broadband modems, mobile devices (smartphones, tablets, etc), Voice-over IP (VoIP) or cordless phones, automation hubs, Wi-Fi home security cameras, and more. Included with the Back-UPS Connect is a 5' county-specific detachable power cord, a removable mobile power pack, removable supports feet, stabilization/wall mounting feet, and a USB cable. It is protected by a limited 3-year repair or replace warranty.
If you own a APC ups backup and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the APC Back-UPS Connect BGE50ML in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the APC Back-UPS Connect BGE50ML:
Specifications
Output
Output Power Capacity 50 W / 84 VA
Max Configurable Power 50 W / 84 VA
Nominal Output Voltage 120 V
Output Frequency (Sync to Mains) 50/60 Hz (±3 Hz)
Output Voltage / Frequency (On Battery) 115 VAC ±8%
50/60 Hz (±1 Hz auto sensing)
Topology Square
Waveform Type Stepped approximation to a sinewave
Output Connections 2 x NEMA 5-15R (Battery Backup)
Input
Nominal Input Voltage 120 V
Maximum Adjustable Input Voltage 88 ~ 142 VAC
Input Frequency 50/60 Hz (± 3 Hz - auto sensing)
Input Voltage Range for Utility Operation 92 ~ 139 VAC (medium sensitivity, default)
88 ~ 142 VAC (low sensitivity)
96 ~ 136 VAC (high sensitivity)
Input Connections NEMA 5-15P
Cord Length 5.0' / 1.5 m
Maximum Input Current 2 A
Input Breaker Capacity 4 A
Batteries & Runtime
Battery Type Lithium-ion
Typical Recharge Time 2.5 hours
USB Ports USB Port 1: 1 A
USB Port 2: 1 A
USB Port 3: 2.4 A universal charging port
Automatic Self Testing Yes
Dimensions 0.9 x 5.1 x 2.9" / 2.3 x 13.0 x 7.4 cm
Weight 0.60 lb / 0.27 kg
Communications & Management
Control Panel LED Status display with On Line : On Battery
Surge Protection and Filtering
Surge Energy Rating 340 J
Environmental
Operating Environment 32 to 104°F / 0 to 40°C
Operating Relative Humidity 0 - 95%
Operating Elevation 0 - 10,000' / 0 - 3,048 m
Storage Temperature 5 to 113°F / -15 to 45°C
Storage Relative Humidity 0 - 95%
Storage Elevation 0 - 50,000' / 0 - 15,240 m
Audible Noise 32 dBA at 3.3' / 1.0 m from surface of unit
Conformance
Approvals California (CEC) Battery Charger, cTUVus, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-4-8, EN61000-4-2, EN61000-4-3, FCC Part 15 Class B, ICES-003, UN 38.3
Sustainable Offer Status
RoHS Compliant
REACH REACH: Contains No SVHCs
Battery Directive Compliant
Physical
Color White
Dimensions 2.13 x 7.72 x 7.01" / 5.41 x 19.61 x 17.81 cm
Weight 2.87 lb / 1.30 kg
Packaging Info
Package Weight 4.25 lb
Box Dimensions (LxWxH) 13.543 x 9.213 x 2.677"
APC Back-UPS Connect BGE50ML: My Life
The user manual for the APC Back-UPS Connect BGE50ML can be downloaded in .pdf format if it did not come with your new ups backup, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other APC users keep a unique electronic library for APC ups backups, where you can use our link to download the user manual for the APC Back-UPS Connect BGE50ML.

The user manual lists all of the functions of the APC Back-UPS Connect BGE50ML, all the basic and advanced features and tells you how to use the ups backup. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from APC service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the APC Back-UPS Connect BGE50ML. User manuals are also available on the APC website under Computers & Solutions - Power - UPS Backup.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the APC Back-UPS Connect BGE50ML

Post new comment to APC Back-UPS Connect BGE50ML

Subject: Revive the battery
Date: 02.01.2024 12:35:14Author: Don Rusak
Hello, Is the 'pin-out' for the battery pack available. I would like to 'revive' the battery as it does not charge. Worked well on my Milwaukee battery, should work on this one as well.
Reply

Post new comment/question/response regarding the APC Back-UPS Connect BGE50ML

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

Need manual - Sunpak Universal SelfieWand for Smartphones, Point SP-BSW-BK
Posted by: Sam
2024-04-23 19:26:40

Please send...
Yongnuo YN467 Manual - Yongnuo YN-460II Flash Speedlite YN-460II
Posted by: Robert
2024-04-21 16:35:48

Please may I have a PDF copy of the manual? Thank you....
hk EA600 amp - HK AUDIO EA600 600W Class-D Power Amplifier EA600
Posted by: Ky Trinh
2024-04-20 09:31:19

Can you directly connect the ea600 amp to the E110A active subwoofer?...
Manual MU118 - Rolls MU118 Digital Multimeter MU118
Posted by: Benito Camela Vergara
2024-04-19 17:10:17

Manden el manual de servicio y el de usuario...
Ripple after runing - Drytac JM55 Force JetMounter Electric Laminator JM55-FORCE
Posted by: Project Printed
2024-04-19 16:06:58

The laminate continues to ripple after running. Can’t we to do long runs without the laminate rippling and causing damage to print. ...