PDF-MANUALS.com | User manual here!
User manual

User manual Dorrough Dual Analog Loudness Meters 20dB 12-C

Operating instructions and pdf manual for use - Dorrough Dual Analog Loudness Meters 20dB 12-C User manual, User manual Dorrough Dual Analog Loudness Meters 20dB 12-C, Dorrough, Dual, Analog, Loudness, Meters, 20dB, 12-C, Video


User manual for Dorrough Dual Analog Loudness Meters 20dB 12-C

Dorrough  Dual Analog Loudness Meters  20dB 12-C
  • Manufacturer: Dorrough
  • Basic description and contents of package
  • Product classification: Pro Audio - General Accessories - Metering
  • Safety instructions
  • Startup and operation of the metering
  • Tips for setting up your Dorrough
  • Settings and expert assistance
  • Contact Dorrough service
  • Troubleshooting
  • Warranty information
  • Price: 903 USD
We recommend checking out our discussion threads on the Dorrough Dual Analog Loudness Meters 20dB 12-C, which address similar problems with connecting and setting up Metering Dorrough.



User manual for the Dorrough Dual Analog Loudness Meters 20dB 12-C

The user manual for the Dorrough Dual Analog Loudness Meters 20dB 12-C provides necessary instructions for the proper use of the product Pro Audio - General Accessories - Metering.

The Dorrough 12-C Analog Loudness Meter +20dB is dual version of Dorrough's 10-C single-channel loudness monitor. The meter scale allows for 20dB of headroom in 1dB steps. The headroom scale is identical to the AES/EBU Digital Standard.
If you own a Dorrough metering and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Dorrough Dual Analog Loudness Meters 20dB 12-C in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Dorrough Dual Analog Loudness Meters 20dB 12-C:
Input Impedance 20k Ohm balanced, 10k Ohm single-ended, +/- 2%
Common Mode Rejection Ratio 80 dB at 60 Hz, 60 dB at 20 kHz (balanced mode)
Input Sensitivity -10 dB for full-scale display
Maximum Input Level +24 dB before clipping
Signal Path Bandwidth 10 Hz - 25 kHz, +/- .25 dB
Signal Path Distortion Less than 1% THD at 1 kHz, +24 dB input
Sum Error Less than 0.1 dB at 1 kHz
Difference Error Less than 0.1 dB at 1 kHz
Display Resolution Less than 0.1 dB at 1 kHz
Step Size Error +/- 0.25 dB
Absolute Error Full Scale -39 dBu: +/- 0.25 dB model A,B,C
Drift +/- 0.25 dB
Average Time Constant 600 mS, +/- 6%
Peak Acquisition Period 10 uS, to full-scale, sine input 25kHz
Peak Attack Period Virtually Instantaneous
Peak Decay Period 180 mS, from full-scale to all LEDs off (models A, B, C)
Display Update Rate Approximately 10 mS
Display Duty Cycle Display Time, AVERAGE, PEAK HOLD - 75%

Display Time, PEAK - 100%

Power Supply Input Range 117/237 VAC RMS, -20% to +10%, 50-60 Hz
Calibration Controls None Needed
User Controls Left/Right input sensitivity Option DIP Switch

A) Peak Auto [ON]

B) Difference Mode [ON/OFF]

C) Over Level Alarm [ENABLE]

D) Under Level Alarm [ENABLE]

E) Auto ARMP

User Port DB-9 Connector A) Alarm relay closure contacts 1 form C, 1A, 30V AC or DC

 B) Mode control switch (user supplied)

C) PEAK function switch (user supplied)

Dimensions (WxDxH) 8.6 x 3.0 x 2.0" (in.) (3.4 x 1.2 x 0.8cm)
Weight Not Specified by Manufacturer
Packaging Info
Package Weight 1.65 lb
Box Dimensions (LxWxH) 11.4 x 9.2 x 5.1"
The user manual for the Dorrough Dual Analog Loudness Meters 20dB 12-C can be downloaded in .pdf format if it did not come with your new metering, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Dorrough users keep a unique electronic library for Dorrough meterings, where you can use our link to download the user manual for the Dorrough Dual Analog Loudness Meters 20dB 12-C.

The user manual lists all of the functions of the Dorrough Dual Analog Loudness Meters 20dB 12-C, all the basic and advanced features and tells you how to use the metering. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Dorrough service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Dorrough Dual Analog Loudness Meters 20dB 12-C. User manuals are also available on the Dorrough website under Pro Audio - General Accessories - Metering.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Dorrough Dual Analog Loudness Meters 20dB 12-C - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the Dorrough Dual Analog Loudness Meters 20dB 12-C

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!





Current discussions
Most recently discussed products:

Keyboard typing sensitivity - ZAGG Folio Backlit Tablet Keyboard Case for iPad Air ID6ZFK-BB0
Posted by: Engsberg
2017-08-19 19:12:37

How do I adjust the keyboard buttons so that they are less sensitive when I type? When typing, there often appears an unwanted period after one word and a capital letter of the next word. That very thing happened three times while I was typing this...
How do I download? - Trijicon 4x32 ACOG Riflescope TA01NSN
Posted by: Mark
2017-08-19 16:58:58

I cannot find the link to download the manual I'm looking for. What do I do?...
assitance with SETTING UP AP1832I - Cisco Aironet 1832i Dual-Band 802.11ac Wave 2 AIR-AP1832I-B-K9C
Posted by: lamech
2017-08-19 07:55:42

AM having challnges with settup this device ive tried to use the default password of Cisco but it can allow me to use a console and configure it. it just brings dtls reced packet caused dtls to close connection...
nanogrid wont turn all the way off - BioLite NanoGrid LED Area Lighting and Charging System LCA
Posted by: jimlobell
2017-08-19 06:46:52

I noticed coming back to camp tonight that one side of the lamp is lit very dimly, and I can't get it to turn off. what to do?...
manual - Cooler Master GeminII M4 CPU Cooler RR-GMM4-16PK-R2
Posted by: FIDEL GARCIA LUNA
2017-08-19 05:30:20

necesito el manual para instalacion del cooler master para mas seguridad ,, gracias...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF user manuals
sitemap.txt