PDF-MANUALS.com | User manual here!
User manual

User manual Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO

Operating instructions and pdf manual for use - Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO User manual, User manual Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO, Neumann, TLM, 170, R, Multi-Pattern, Large-D


User manual for Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO

Overall rating 5.0
Overall Rating: 5.0

100% of respondents would recommend this to a friend.
Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO
  • Manufacturer: Neumann
  • Basic description and contents of package
  • Product classification: Pro Audio - Recording - Large Diaphragm Condenser
  • Safety instructions
  • Startup and operation of the large diaphragm condenser
  • Tips for setting up your Neumann
  • Settings and expert assistance
  • Contact Neumann service
  • Troubleshooting
  • Warranty information
Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO
Click to enlarge image

We recommend checking out our discussion threads on the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO, which address similar problems with connecting and setting up Large Diaphragm Condenser Neumann.



User manual for the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO

The user manual for the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO provides necessary instructions for the proper use of the product Pro Audio - Recording - Large Diaphragm Condenser.

The nickel TLM 170 R Multi-Pattern Large-Diaphragm Studio Condenser Microphone from Neumann is a stereo set of two large-diaphragm, multi-pattern condenser microphones that features FET 100 technology, a balanced, transformerless output stage, low self-noise, and an impressive dynamic range.

Five directional characteristics are selectable by means of a rotary switch. In the sixth position, marked "R," the directional patterns can be controlled remotely with the included N 248 power supply. There is no special cable necessary for this purpose. The microphone has at its rear a 10 dB attenuation switch for extremely high sound-pressure levels, and a high-pass filter to suppress structure-borne noise. A second switch at the rear enables the mic to attenuate the frequency response below 100 Hz to suppress undesired structure-borne noise.

The TLM 170 R can be used for many diverse applications in professional recording studios, in broadcasting, film and television, and for semi-professional productions.

The large-diaphragm capsule inside the head grille has a very smooth frequency response for all polar patterns over a wide acceptance angle. The curves are flat and parallel to the 0° frequency curve up to 10 kHz within an angle of ± 100°. As a result, the TLM 170 R has a very even diffuse-field response for all polar patterns. This is important in a reverberant environment, as more reflections arrive at the microphone from different directions. The acoustic information is not affected in its tonal quality when recorded by the microphone. This characteristic is achieved without resorting to corrective-resonance effects.

The microphone maintains an great impulse response reproducing transient music and speech without any coloration. The capsule is elastically mounted to avoid any structure-borne noise that could interfere with its operation.

When compared to the standard cardioid pattern, the hypercardioid characteristic suppresses sound from the side more efficiently. The wide-angle polar pattern is especially useful to record large sound sources. The N 248 controls the polar pattern remotely by varying the phantom voltage. The range is ± 3V of the nominal 48V value. The rotary switch on the microphone must be in the position R, remote control. In this switch position the TLM 170 R microphone analyzes the absolute value of the phantom power and selects the corresponding polar pattern. A standard 3-pin microphone cable is used, similar to the microphone's conventional operation. Cable lengths may be up to 1000'.

With TLM technology, the usual output transformer is replaced by an electronic circuit. As with traditional transformers, it ensures good common-mode rejection, and prevents RF interference, that may influence the balanced audio signal.

A tilting side bracket to attach the microphone to booms or stands is included. The bracket is equipped with rubber elements that effectively protect the microphone from mechanical shock. If necessary, it can be mounted on the other side of the microphone as well. When using the IC 4 cable, the bracket and its holder need to be removed. The microphone can then be connected to the swivel-mount connector of the cable.

All exposed surfaces of the capsule, including the diaphragms, are at ground potential. This technology makes them highly immune to electrical and atmospheric interference and contamination through dust particles.
If you own a Neumann large diaphragm condenser and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO:

Go To

Operating Principle Pressure Gradient
Transducer Condenser
Polar Pattern Cardioid, Figure 8, Hypercardioid, Omnidirectional, Wide-Angle Cardioid
Frequency Range 20 Hz to 20 kHz
Signal to Noise Ratio 68 dB CCIR
80 dB A-Weighted
Equivalent Noise Level 26 dB CCIR
14 dB A-Weighted
Maximum SPL 144 dB SPL 0.5%
154 dB SPL 0.5%  dB Pad Engaged
Impedance 50 ohms
Load Impedance 1 kOhms
Sensitivity 8 mV/PA @ 1 kHz into 1 kOhms
Power Requirements 48 V+/- 4 V
Output Connectors 3-pin XLR
Operating Current Consumption 3 µA
General
Length 5.98" (152 mm)
Diameter 2.36" (60 mm)
Weight 22.05 oz (625 g)
The user manual for the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO can be downloaded in .pdf format if it did not come with your new large diaphragm condenser, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Neumann users keep a unique electronic library for Neumann large diaphragm condensers, where you can use our link to download the user manual for the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO.

The user manual lists all of the functions of the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO, all the basic and advanced features and tells you how to use the large diaphragm condenser. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Neumann service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO. User manuals are also available on the Neumann website under Pro Audio - Recording - Large Diaphragm Condenser.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the Neumann TLM 170 R Multi-Pattern Large-Diaphragm TLM 170 R STEREO

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

Simmons 6-24x50 - Simmons 6-24x50 Predator Varmint Riflescope 656245
Posted by: Stuart Williams
2024-03-26 12:36:48

I have located manual for this on your site but how do I download / print it please ?...
USER MANUAL TSP2 17 BUN - Telmax TSP2-17-BUN Dual 17" Presidential TSP2-17BUN
Posted by: AYO
2024-03-26 10:07:35

MANUAL REQUIRED TO SET UP...
lens servo - Fujinon ESM-15A-SA Digital Servo Unit for Fujinon ESM-15A-SA
Posted by: julia yoko
2024-03-25 22:07:20

i would like to know where the lens manual can be found...
NEPVS14-17 - ITT Night Enforcer PVS-14 Pinnacle Night Vision ITTE-NEPVS14-17
Posted by: Keller Bradshaw
2024-03-25 17:57:35

Hi, I would like a user manual for the NEPVS14-17...
YS 03 above water - Sea & Sea YS-03 Universal Lighting System SS-03541
Posted by: sameer
2024-03-24 22:26:52

Hello Would like to know is it safe to use YS 03 strobe outside water for practice purpose ? Regards...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx