|
User manual for RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE
- Manufacturer: RME
- Basic description and contents of package
- Product classification: Pro Audio - Computer Audio - Format Converters
- Safety instructions
- Startup and operation of the format converters
- Tips for setting up your RME
- Settings and expert assistance
- Contact RME service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE,
which address similar problems with connecting and setting up Format Converters RME.
|
User manual for the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE
The user manual for the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE provides
necessary instructions for the proper use of the product Pro Audio - Computer Audio - Format Converters.
The RME ADI-6432R BNC 64-Channel 192 kHz MADI/AES Format Converter (Single-Mode) offers broadcasters the ease of integration and fail-safe operation through the utilization of industry standard BNC connectors and dual redundant power supplies, while offering 64 channels of I/O capability. The BNC version targets broadcast and professional users who require AES-3id connections - coaxial 75Ω cables with up to 984.2' (300m) length. Typical applications include 2 ADI-6432R converter used as digital multicore, or 1 unit used as an AES-3id frontend for the HDSPe MADI card. Up to 192 kHz at 24 bits is supported. With the built-in 2 height units, the ADI-6432R BNC converter provides enough space for all connectors and control elements. AES-3id, an extension to the AES-3 standard also known as AES/EBU, carries the exact same data as the latter, but uses a different cable (75Ω unbalanced instead of 110Ω balanced) with different connectors (BNC instead of XLR) and low voltage (1 Vpp instead of 4 Vpp). Therefore, the ADI-6432R BNC converter has 64 BNC connectors on its back. The ADI-6432R BNC Converter also provides both coaxial (BNC) and optical (SC plug to multi-mode glass fiber) MADI connectors. MADI handles 64 channels of 24-bit audio at sampling frequencies up to 48 kHz, 32 channels up to 96 kHz, and 16 channels up to 192 kHz. All channels are transferred across a single cable, either coaxial (BNC) or optical network cable. In both cases, cable lengths of more than 328' (100m) can be achieved. The ADI-6432R Converter accepts 56-channel and 64-channel MADI formats, as well as 96k frame at its input, and can be set to generate those formats at its output. The ADI-6432R Converter, available with Single-Mode MADI connectors, is compatible to existing single-mode networks and to MADI signal distribution over extremely long distances (up to 10km).
|
If you own a RME format converters and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE:
Input/Output | MADI: 1 x BNC, 1 x optical AES-3id: 32 x BNC (coaxial 75 Ω) | Word Clock | Input: BNC, Signal Adaptation Circuit (functional from 1.2 Vpp) Output: BNC, low impedance driver stage, 4 Vpp into 75 Ω, short-circuit-proof | MIDI In/Out | Via two 5-pin DIN jacks | COM Ports | RS232 via 9-pin D-sub, 9600 / 19200 / 115200 Baud | Sync | MADI, AES, word clock, and internal | Varipitch | By input signal or word clock | Sampling Frequency | 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (sync/word clock) | Sample Rate | MADI: 32 to 192 kHz, word clock: 27 to 200 kHz, AES: 28 to 200 kHz | Jitter | Internal Clock < 1 ns, Word Clock In < 2 ns, AES-3id In < 2 ns Suppression: >30 dB (2.4 kHz) Sensitivity: all PLLs operate error-free even at 100 ns | Power Supply | Internal switching mode PS, 100 to 240 VAC, 20 W | Dimensions (W x H x D) | 19.0 x 3.4 x 7.8" (483.0 x 88.0 x 200.0 mm) | |
The user manual for the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE can be downloaded in .pdf
format if it did not come with your new format converters, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other RME users keep a unique electronic library
for RME format converterss,
where you can use our link to download the user manual for the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE.
The user manual lists all of the functions of the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE,
all the basic and advanced features and tells you how to use the format converters.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from RME service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE. User manuals are also
available on the RME website under Pro Audio - Computer Audio - Format Converters.
Question and answer discussion forum concerning user instructions and resolving problems with the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the RME ADI-6432R BNC 64-Channel 192 kHz ADI6432 R BNC SINGLE
|
|
|
|
|