PDF-MANUALS.com | User manual here!
User manual

User manual Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP

Operating instructions and pdf manual for use - Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP User manual, User manual Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP, Turbosound, 10000DP, 4-Channel, Powered, Loudspeaker, 10000D


User manual for Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP

Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP
  • Manufacturer: Turbosound
  • Basic description and contents of package
  • Product classification: Pro Audio - Live Sound - Power Amplifiers
  • Safety instructions
  • Startup and operation of the power amplifiers
  • Tips for setting up your Turbosound
  • Settings and expert assistance
  • Contact Turbosound service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP, which address similar problems with connecting and setting up Power Amplifiers Turbosound.



User manual for the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP

The user manual for the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP provides necessary instructions for the proper use of the product Pro Audio - Live Sound - Power Amplifiers.

The Turbosound 10000DP 4-Channel Powered Loudspeaker Management System is designed for high power professional live sound reinforcement applications. The unit comes in a 2RU chassis and works with the Flashline large format line array integrated loudspeaker system. Each channel is rated to over 2350W at 2 Ohms;, 2300W at 4 Ohms, 1300W at 8 Ohms, or 660W at 16 Ohms. The amplifier can also be bridged to deliver 4600W at 8 Ohms and 4700W at 4 Ohms.

Advanced features include Lake signal processing, Dante networked audio signal distribution, real-time performance monitoring, and accurate load verification. The system utilizes a universal power supply with Power Factor Correction (PFC) that allows for extended bursts of power without sagging power rails or bursts of low frequency beats from affecting high and mid-frequency headroom.

Each amplifier channel can handle a different impedance and depending upon the application, more power can be delivered to the channel(s) that need it while still leaving peak voltage accessible to all channels. A new set of limiter profiles can be used to improve the subjective performance of the system when the need for perceived higher SPL exceeds the allowable actual SPL limitations of a room.

To ensure the show will go on with uninterrupted power delivery to the speakers, the power management system utilizes a proprietary Breaker Emulation Limiter (BEL) to prevent tripping the mains breaker of the venue. Advanced peak limiting circuits keep the output devices below the thermal protection threshold and within acceptable operating tolerances. If the mains voltage begins sagging, Under-Voltage Limiting (UVL) ensures continuous operation, even if the supply drops to as low as 65 V.

The amplifier comes preloaded with optional settings that have been specifically tailored to different Turbosound loudspeakers.
If you own a Turbosound power amplifiers and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP:
Specifications
    Number of Inputs 2 channels

    Analog to digital: 2 inputs x 2 link
    Number of Outputs 4
    Peak Output Capacity 10,800 W
    Voltage 153 V peak per channel
    Current 49 A peak
    Connectors 2x XLR-3
    4x XLR-3
    1x Neutrik speakON NLT8
    2x Neutrik speakON NLT4
    2x RJ45 ethercon
    1x Neutrik powerCON 32A
    Power Output Per channel
    2350 W into 2 Ohms
    2300 W into 4 Ohms
    1300 W into 8 Ohms
    660 W into 16 Ohms

    Bridged
    4600 W into 8 Ohms
    4700 W into 4 Ohms
    Frequency Response ±0.5 dB (1 W into 8 Ω): 20 to 20,000 Hz
    THD+N From 20 to 20,000 Hz for 1 W: <0.05%
    At 1,000 Hz and 1 dB below clipping <0.04%

    Sample Rate converter: 0.00003% from 20 to 20,000 Hz unweighted

    Analog to Digital inputs:
    0.00022% typical at 1,000 Hz unweighted at +26 dBu headroom setting
    0.00033% typical at 20 to 20,000 Hz unweighted at +26 dBu headroom setting
    Dynamic Range With Analog Inputs: > 112 dB
    Common Mode Rejection >74 dB from 20 to 20,000 Hz
    Data Path Width 32 bit floating point at 96 kHz
    Propogation Delay Straight path analog server input to amp: 1.61 ms
    AES 96 kHz to analog input: 1.68 ms
    Input Sensitivity +12 or +26 dBu
    Limiter Adjustable Inter-Sample Voltage Peak Limiter (ISVPL): 17.8 to 153 V, step size 0.1
    Current Average Limiter (CAL) > 300 ms: 25 A RMS
    MaxRMS: Yes
    MaxPeak: Yes
    Output Attenuator: -inf to 0 dB, step size 0.25 dB
    Sample Rates 48 and 96 kHz
    Network Latency 0.8, 1.3, 4 ms
    User Interface
    Back Panel I/O Ports AES / EBU / I/O (input+link): 2x 3-pin XLR
    Analog, 2-channel I/O (input+link): 4x 3-pin XLR, electronically balanced
    Output Connectors: Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)
    Auto 10/100, Auto Uplink: 2x RJ45 etherCon
    Back Panel Controls Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)
    Mains Detachable Neutrik PowerCon rated at 250V/32A
    Cooling Two fans, front-rear airflow, temperature controlled speed
    Display 2.5" daylight readable LCD
    Indicators RGB LEDs and detailed fault description on display for fault/warning/limit/clip
    Mute 8 functions provided
    Operating Voltage 140 to 265 V
    70 to 135 V
    Inrush Current Max 5 A
    Power Management Power Average Limiter (PAL)
    Power Factor Correction (PFC)
    Breaker Emulation Limiter (BEL)
    Under Voltage Limiter (UVL)
    Approvals CE
    ANSI/UL 60065 (ETL)
    CSA C22.2 NO. 60065
    FCC
    Dimensions (W x H x D) 19.0 x 3.46 x 15.2" (483 x 88 x 386 mm)
    Weight 30.0 lb (13.5 kg)
    The user manual for the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP can be downloaded in .pdf format if it did not come with your new power amplifiers, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Turbosound users keep a unique electronic library for Turbosound power amplifierss, where you can use our link to download the user manual for the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP.

    The user manual lists all of the functions of the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP, all the basic and advanced features and tells you how to use the power amplifiers. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Turbosound service.

    If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP. User manuals are also available on the Turbosound website under Pro Audio - Live Sound - Power Amplifiers.



    Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP - no comments have been made yet - be the first to add a comment

    Post new comment/question/response regarding the Turbosound 10000DP 4-Channel Powered Loudspeaker 10000DP

    Fields marked with * must be filled out.
    Your name *:
    E-mail :
    Subject *:
    Message text *:
    Enter the code *:
    (spam block)
    "manual"
    If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

     

    Can't find what you're looking for? Try Google Search!



    Current discussions
    Most recently discussed products:

    MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
    Posted by: Jae Gil, Ha
    2024-04-25 09:48:07

    needs manual file...
    Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
    Posted by: Judy Whiteley
    2024-04-24 16:51:27

    Please send user’s manual in normal size print...
    Need manual - Sunpak Universal SelfieWand for Smartphones, Point SP-BSW-BK
    Posted by: Sam
    2024-04-23 19:26:40

    Please send...
    Yongnuo YN467 Manual - Yongnuo YN-460II Flash Speedlite YN-460II
    Posted by: Robert
    2024-04-21 16:35:48

    Please may I have a PDF copy of the manual? Thank you....
    hk EA600 amp - HK AUDIO EA600 600W Class-D Power Amplifier EA600
    Posted by: Ky Trinh
    2024-04-20 09:31:19

    Can you directly connect the ea600 amp to the E110A active subwoofer?...