|
User manual for Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F
- Manufacturer: Wohler
- Basic description and contents of package
- Product classification: Pro Audio - Computer Audio - AD/DA Converters
- Safety instructions
- Startup and operation of the ad/da converters
- Tips for setting up your Wohler
- Settings and expert assistance
- Contact Wohler service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F,
which address similar problems with connecting and setting up AD/DA Converters Wohler.
|
User manual for the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F
The user manual for the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F provides
necessary instructions for the proper use of the product Pro Audio - Computer Audio - AD/DA Converters.
The Wohler AMP1A-30 2 Channel Analog Audio Monitor is a single rack space 2-channel audio monitoring system. It is optimized for the playback of audio in a near field working environment, where you need to be seated one to three feet from the source. The AMP1A-30 can be used in a variety of applications such as VTR bays, mobile production vehicles, teleconferencing installations, multimedia systems, satellite links, cable TV facilities, and on-air radio studios.
The unit features a stereo pair of self-powered speakers for the mid and high range in addition to two speakers dedicated to frequencies below 500Hz. These four speakers provide a combined peak output of 98 dB SPL at a distance of two feet. The front panel ¼" headphone jack allows for quiet monitoring of your sound source by muting the main speakers.
Designed to reveal problems with the quality of your sound source, the AMP1A-30 has a high frequency response that was shaped to boost the range of whine and hiss. The electronic cancellation of lower frequencies allows you to identify phase issues with your audio feed.
|
If you own a Wohler ad/da converters and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F:
Inputs | 2x XLR | Outputs | 2x XLR 1x 1/4" headphone jack | Peak Acoustic Output at 2 feet | 98 dB SPL | Frequency Response | 1/6 octave: 80 Hz to 16 kHz (+ or - 7 dB); (-10 dB @ 50 Hz, 22 kHz) | Level Meters | 2x 30 segment horizontal LEDs Scale: 65 dB (16 to -49 dB factory default for extended VU) Threshold: 0, 4, 6, 8 dBv(='0'), DIP selectable; factory setting is 4 d Dynamics: Simultaneous VU & PPM Resolution: 1 dB | VU Meter | VU Characteristics: Rise time: 300 ms to 99% of full indication Fall time: 300 ms PPM Characteristics: Attack time: 10 ms Decay time: 2 s, 0 to -20 dB | Aural Sound Outputs | Wohler speaker system Headphone (mutes speakers) 2x mid and high speakers 2x woofer speakers | Acoustic Distortion | ≤ 8% @ worst case frequencies above 180 Hz including cabinet resonance, typically < 2% | Electrical Distortion | < 0.15% at any level below limit threshold | Hum and Noise | > -68 dB below full output | Input Level | For maximum output: 0 dB balanced (volume full on) Overload: 26 dBv balanced | Input Impedance | > 40 kΩ balanced | Magnetic Shielding | < 1 Gauss any adjacent surface | Power Output | RMS each side: 10 W transient/5 W continuous; RMS bass: 20 W Transient/10 W Continuous | Power Consumption | 35 W | Power Requirements | Power to the unit is 24 V DC, 3.0 A The external power supply then connects to mains power: 100 to 240 VAC ± 10%, 50/60Hz | Space requirements | 1 RU in a standard 19" rack | Dimensions (HxWxD) | 2 x 19 x 12" (45 x 483 x 298 mm ) | Weight | 14 lb (6 kg) | |
The user manual for the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F can be downloaded in .pdf
format if it did not come with your new ad/da converters, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Wohler users keep a unique electronic library
for Wohler ad/da converterss,
where you can use our link to download the user manual for the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F.
The user manual lists all of the functions of the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F,
all the basic and advanced features and tells you how to use the ad/da converters.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Wohler service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F. User manuals are also
available on the Wohler website under Pro Audio - Computer Audio - AD/DA Converters.
Question and answer discussion forum concerning user instructions and resolving problems with the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Wohler AMP1A-30 2 Channel Analog Audio Monitor 8100-0070F
|
|
|
|
|