User manual Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C
Operating instructions and pdf manual for use - Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C User manual, User manual Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C, Aiphone, LEF-10C, 10-Call, Semi-Flush, Mount,
User manual for Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C
We recommend checking out our discussion threads on the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C,
which address similar problems with connecting and setting up Indoor Stations Aiphone.
User manual for the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C
The user manual for the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C provides
necessary instructions for the proper use of the product Surveillance - Intercoms - Indoor Stations.
The LEF-10C 10-Call Semi-Flush Mount Master Station from Aiphone is a selective-calling open-voice style master station, used to answer calls from other remotes or masters. The LEF-10C can be part of a larger system with the ability to communicate with ten other stations, and make an All Call and/or receive background music (requires All Call/Chime Adapter, available separately). The master station flush mounts into a wall.
If you own a Aiphone indoor stations and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C:
Specifications
Compatible with
LE-series Sub/Door Stations BG-10C All Call/Chime Adapter BGR-10A Radio/All Call/Chime Unit PS-1225UL Power Supply
Power Source
12 VDC, 300 mA per station Use PS-1225UL power supply (sold separately); one power supply is required per system
Press-to-talk, release-to-listen at master station Hands free response at responding station
Talk Path
1 talk path, occupied LED glows when in use
Capacity
Up to 11 stations, intermixable
Wiring
Master Stations Communication only: 5 common wires +1 per station in the system, looped Communication and All Call: 8 common wires + 1 per station in the system, looped Communcation, All Call, Door Release: 9 common wires + 1 per station in the system, looped.
Standard Sub: 2 common wires + 1 per station on the loop LE-C/CN: 4 common wires + 2 per station on the loop Single Master System: 2 wires per sub station, homerun
Distance
Wiring: 650.0' (198.1 m) with 22AWG 1,600' (488 m) with 18AWG
Release
110 VAC / 1A, 24 VDC / 1A (selective door release or control of external capacity for door release devices), on output of RY-PA relay.)
Contact
Select Switch Rating: 12 VDC, 30 mA (K1 to K5 terminals for external device control)
Speaker
Sensitivity: 40 dB
Total Harmonic Distortion
Less than 5% at rated output power
Signal to Noise Ratio
60 dB
Frequency Response
-3 dB, 770 to 6,800 Hz
Dimensions (H x W x D)
9.4 x 7.8 x 1.3" (238.7 x 198.1 x 33.0 mm)
Weight
1.50 lb (0.68 kg)
The user manual for the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C can be downloaded in .pdf
format if it did not come with your new indoor stations, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Aiphone users keep a unique electronic library
for Aiphone indoor stationss,
where you can use our link to download the user manual for the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C.
The user manual lists all of the functions of the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C,
all the basic and advanced features and tells you how to use the indoor stations.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Aiphone service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C. User manuals are also
available on the Aiphone website under Surveillance - Intercoms - Indoor Stations.
Question and answer discussion forum concerning user instructions and resolving problems with the Aiphone LEF-10C 10-Call Semi-Flush Mount Master Station LEF-10C - no comments have been made yet - be the first to add a comment
Can you directly connect the ea600 amp to the E110A active subwoofer?...Manual MU118 - Rolls MU118 Digital Multimeter MU118 Posted by: Benito Camela Vergara 2024-04-19 17:10:17