User manual for Belden RG59 Plenum Cable (500', Black)
- Manufacturer: Belden
- Basic description and contents of package
- Product classification: Pro Audio - Installation Sound - Bulk Cable
- Safety instructions
- Startup and operation of the bulk cable
- Tips for setting up your Belden
- Settings and expert assistance
- Contact Belden service
- Troubleshooting
- Warranty information
- Price: 800 USD
|
We recommend checking out our discussion threads on the Belden RG59 Plenum Cable (500', Black),
which address similar problems with connecting and setting up Bulk Cable Belden.
|
User manual for the Belden RG59 Plenum Cable (500', Black)
The user manual for the Belden RG59 Plenum Cable (500', Black) provides
necessary instructions for the proper use of the product Pro Audio - Installation Sound - Bulk Cable.
The black RG59 Plenum Cable (500') from Belden features 20 AWG solid 0.03" (0.08cm) bare copper conductor, plenum, foam FEP insulation, Duofoil + tinned copper braid shield (95% coverage), and Flamarrest jacket.
|
If you own a Belden bulk cable and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Belden RG59 Plenum Cable (500', Black) in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Belden RG59 Plenum Cable (500', Black):
Conductor | Number of Coax: 1 AWG: 20 Stranding: Solid Conductor Material: BC (Bare Copper) Diameter: 0.03" (0.06 cm) | Insulation Material | Insulation Trade Name: Teflon Insulation Material: FFEP (Foam Fluorinated Ethylene Propylene) Diameter: 0.14" (0.33 cm) | Outer Shield Material | Outer Shield Trade Name: Duofoil Type: Tape, Braid Outer Shield Material: Aluminum Foil Polyester, Tape Aluminum Foil, TC (Tinned Copper) Coverage (%): 100, 95 | Outer Jacket Material | Outer Jacket Trade Name: Flamarrest Outer Jacket Material: PVC (Polyvinyl Chloride) | Cable | Nominal Diameter: 0.2" (0.5 cm) | Impedance | 75 Ω | Inductance | 0.1 µH/feet | Capacitance | Nominal Capacitance Conductor to Shield: 16.1 pF/feet | Velocity of Propagation | 84% | Conductor DC Resistance | 10 Ω/1,000' at 68°F (20°C) | Delay | 1.21 ns/feet | Outer Shield DC Resistance | 3.2 Ω/1,000' at 68°F (20°C) | Maximum Voltage | 300 Vrms (UL) 18.0 kV (Nominal breakdown voltage between conductors) 16.9 kV (Nominal breakdown voltage conductors to shield) | Return Loss | Start Frequency: 5 MHz, 1,600 MHz Stop Frequency: 1,600 MHz, 4,500 MHz Minimum RL (dB): 23, 21 | Attenuation | Frequency (MHz): 1, Attenuation (dB/100'): 0.29 Frequency (MHz): 3.58, Attenuation (dB/100'): 0.62 Frequency (MHz): 5, Attenuation (dB/100'): 0.70 Frequency (MHz): 7, Attenuation (dB/100'): 0.82 Frequency (MHz): 10, Attenuation (dB/100'): 1.05 Frequency (MHz): 67.5, Attenuation (dB/100'): 2.20 Frequency (MHz): 71.5, Attenuation (dB/100'): 2.25 Frequency (MHz): 100, Attenuation (dB/100'): 2.70 Frequency (MHz): 135, Attenuation (dB/100'): 3.20 Frequency (MHz): 143, Attenuation (dB/100'): 3.25 Frequency (MHz): 180, Attenuation (dB/100'): 3.65 Frequency (MHz): 270, Attenuation (dB/100'): 4.55 Frequency (MHz): 360, Attenuation (dB/100'): 5.25 Frequency (MHz): 540, Attenuation (dB/100'): 6.4 Frequency (MHz): 720, Attenuation (dB/100'): 7.3 Frequency (MHz): 750, Attenuation (dB/100'): 7.5 Frequency (MHz): 1000, Attenuation (dB/100'): 9.4 Frequency (MHz): 1500, Attenuation (dB/100'): 12.8 Frequency (MHz): 2250, Attenuation (dB/100'): 17.5 Frequency (MHz): 3000, Attenuation (dB/100'): 21.9 | Compliance | NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II) EU CE Mark EU Directive 2000/53/EC (ELV) EU Directive 2002/95/EC (RoHS) EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE) EU Directive 2003/11/EC (BFR) CA Prop 65 (CJ for Wire & Cable) MII Order #39 (China RoHS) RG Type: 59/U UL Flame Test: NFPA 262 | Suitability | Indoor | Plenum | Yes Non-Plenum Number: 1505A | Temperature | Operating Temperature Range: -4 to 167°F (-20 to +75°C) Non-UL Temperature Rating: 167°F (75°C) | Tension Control | Recommended Pulling Tension: 68.0 lb (30.8 kg) maximum | Bend Radius | 2.0" (6.1 cm) | Weight | 29.00 lb (13.15 kg) | Package Weight | 16.4 lb | Box Dimensions (LxWxH) | 8.189 x 6.693 x 5.748" | |
The user manual for the Belden RG59 Plenum Cable (500', Black) can be downloaded in .pdf
format if it did not come with your new bulk cable, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Belden users keep a unique electronic library
for Belden bulk cables,
where you can use our link to download the user manual for the Belden RG59 Plenum Cable (500', Black).
The user manual lists all of the functions of the Belden RG59 Plenum Cable (500', Black),
all the basic and advanced features and tells you how to use the bulk cable.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Belden service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Belden RG59 Plenum Cable (500', Black). User manuals are also
available on the Belden website under Pro Audio - Installation Sound - Bulk Cable.
Question and answer discussion forum concerning user instructions and resolving problems with the Belden RG59 Plenum Cable (500', Black) - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Belden RG59 Plenum Cable (500', Black)
|
|
|
|
|