User manual Neumann D-01 Digital Studio Microphone D-01
Operating instructions and pdf manual for use - Neumann D-01 Digital Studio Microphone D-01 User manual, User manual Neumann D-01 Digital Studio Microphone D-01, Neumann, D-01, Digital, Studio, Microphone, D-01, Video
User manual for Neumann D-01 Digital Studio Microphone D-01
Manufacturer: Neumann
Basic description and contents of package
Product classification: Pro Audio - Recording - Large Diaphragm Condenser
Safety instructions
Startup and operation of the large diaphragm condenser
Tips for setting up your Neumann
Settings and expert assistance
Contact Neumann service
Troubleshooting
Warranty information
We recommend checking out our discussion threads on the Neumann D-01 Digital Studio Microphone D-01,
which address similar problems with connecting and setting up Large Diaphragm Condenser Neumann.
User manual for the Neumann D-01 Digital Studio Microphone D-01
The user manual for the Neumann D-01 Digital Studio Microphone D-01 provides
necessary instructions for the proper use of the product Pro Audio - Recording - Large Diaphragm Condenser.
The Neumann D-01 Digital Studio Microphone eliminates the need for external analog pre-amplifiers and analog-to-digital converters. Instead, the analog to digital conversion occurs within the microphone capsule and sends a digital signal to either a digital microphone interface or an AES/EBU connection kit according to the AES42 standard for use with an AES/EBU or S/PDIF audio interface. Multiple Digital Microphone Interfaces and other external equipment can be synchronized via the unit's internal word clock and BNC output. Fifteen different directional characteristics can then be controlled using Neumann's remote control software.
The benefits of digital microphones include a dynamic range of over 130 dB and less errors, nonlinear distortion, and noise voltages within the signal chain. Additionally, having the analog-to-digital conversion at the level of the microphone capsule enables DSP functions such as peak limiting to be integrated into the microphone itself.
The internal Neumann A/D converter is optimized for the signal and impedance parameters of the capsule. This also eliminates the challenges sometimes encountered when matching a Neumann microphone to a pre-amplifier and external A/D converter. The microphone is universally applicable and particularly suitable for applications where maximum resolution and transparency are desired.
If you own a Neumann large diaphragm condenser and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Neumann D-01 Digital Studio Microphone D-01 in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Neumann D-01 Digital Studio Microphone D-01:
Specifications
Transducer
Acoustic: K 07 large double-diaphragm capsule, diameter 1.2" (30.0 mm) with protected internal electrodes
Characteristics
Directional: 15 remote controllable polar patterns, from omni to cardioid to figure-8
Frequency Response
20 to 20,000 Hz
Sensitivity
Free-Field: -44 dBFS (at 1 kHz, re 94 dBSPL)
Equivalent Noise Level
CCIR: 19 dB A-Weighted: 8 dB-A (According to IEC 60268-1; CCIR-weighting according to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS)
Signal-to-Noise Ratio
CCIR: 75 dB A-Weighted: 86 dB (According to IEC 60268-1; CCIR-weighting according to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS)
Maximum SPL
At 0 dBFS: 138 dBSPL
Dynamic Range
A-Weighted: 130 dB (according to IEC 60268-1; CCIR-weighting according to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS)
The user manual for the Neumann D-01 Digital Studio Microphone D-01 can be downloaded in .pdf
format if it did not come with your new large diaphragm condenser, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Neumann users keep a unique electronic library
for Neumann large diaphragm condensers,
where you can use our link to download the user manual for the Neumann D-01 Digital Studio Microphone D-01.
The user manual lists all of the functions of the Neumann D-01 Digital Studio Microphone D-01,
all the basic and advanced features and tells you how to use the large diaphragm condenser.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Neumann service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Neumann D-01 Digital Studio Microphone D-01. User manuals are also
available on the Neumann website under Pro Audio - Recording - Large Diaphragm Condenser.
Question and answer discussion forum concerning user instructions and resolving problems with the Neumann D-01 Digital Studio Microphone D-01 - no comments have been made yet - be the first to add a comment
Please, send me the user manual for Ibanez M510E-BS Mandolin in PDF. Thak You!...Vortex 8x42 HD Talon binocular Manual - Vortex Talon HD 8x42 Roof Prism Binocular TLN-4208-HD Posted by: Pierre Gagnon 2024-04-12 23:06:37
Would like your PDF manual.
Thanks for this convenience.
Fantastic binocular....