|
User manual for Quested Q412D Active 3-Way Monitoring System with Amp and Q412D
- Manufacturer: Quested
- Basic description and contents of package
- Product classification: Pro Audio - Recording - Studio Monitors
- Safety instructions
- Startup and operation of the studio monitors
- Tips for setting up your Quested
- Settings and expert assistance
- Contact Quested service
- Troubleshooting
- Warranty information
- Price: 41 USD
|
We recommend checking out our discussion threads on the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D,
which address similar problems with connecting and setting up Studio Monitors Quested.
|
User manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D
The user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D provides
necessary instructions for the proper use of the product Pro Audio - Recording - Studio Monitors.
The Q412D Monitoring System from Quested includes a three-way active speaker designed to be soffit-mounted main monitors for large control rooms. The system comprises four 12" low frequency drivers, one 3" mid frequency driver, and one 1.5" high frequency driver that combine to provide effortless and articulate performance with sound pressure levels of 130 dB.
|
If you own a Quested studio monitors and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D:
Driver | Bass: 4 x 12" / 30.5 cm Mid: 3" / 7.5 cm High: 1.5" / 3.7 cm | Maximum SPL | 130 dB at 1 m | Frequency Response | 20 Hz to 20 kHz ±2 dB | Input Connections | Gold Plated Binding Post: 3 x twin pair Accepts 0.2" / 0.4 cm banana plugs or bare wires | Amplifier (Power) | Bass: 1850 W (RMS) into 2 ohms Mid: 450 W (RMS) into 8 ohms High 450: 450 W (RMS) into 8 ohms | Crossover Point | Low: 450 HZ Linkwitz-Riley 24 dB/oct High: 4.5 kHz Linkwitz-Riley 24 dB/oct | Dimensions (W x H x D) | 37.0 x 34.6 x 26.4" / 94.0 x 88.0 x 67.0 cm | Weight | 286.6 lb / 130.0 kg | Power Rating | 450 W into 8 ohms 770 W into 4 ohms | Damping Factor | 400 @ 8 ohms 1 kHz | Input Sensitivity | +7 dBm | Input Impedance | 10 kOhms | Gain | 33 dB | Frequency Response | 20 Hz to 20 kHz | Signal to Noise Ratio | Not specified by manufacturer | Total Harmonic Distortion (THD) | 0.005% | Input Connections | 3-pin XLR | Output Connectors | Shrouded Binding Posts: 4 mm | Controls Front Panel | On/Off, rotary potentiometers, mute | Controls Rear Panel | 2/4 or 4/8 switch, stereo or bridged switch | Indicators | Peak meters, mute, fault/DC & limit, bridged, power, temperature | Cooling | Temperature warnings and 2 fans to assist | Power Consumption | Not specified by manufacturer | Power Requirements | 230 VAC @ 10 A max 120 VAC @ 20 A max | Dimensions | 19 x 1.75 x 15" (48.2 x 8.8 x 38.1cm) | Weight | 51 lbs (23kg) | Power Rating | Watts RMS per channel 16 ohms: 400 8 ohms: 750 4 ohms: 1250 3 ohms: 1600 2 ohms: 1800 | Damping Factor | 1 kHz, 8 ohms | Input Sensitivity | 80 dB | Input Impedance | 10 kOhms | Gain | 33 dB | Frequency Response | 20 Hz to 20 kHz | Signal to Noise Ratio | Not specified by manufacturer | Total Harmonic Distortion (THD) | 0.008% | Input Connectors | 3-pin XLR | Output Connectors | Shrouded Binding Posts: 4 mm | Controls Front Panel | Level controls, mute, link switch, signal limiters, temperature | Controls Rear Panel | 2 ohm and bridged LEDs | Indicators | Level indicators, fault indicators, clip warning, 2 ohms, and bridged LEDs | Cooling | Cooling fans and temperature controls | Power Consumption | Not specified by manufacturer | Power Requirements | 230 VAC @ 20.0 A max 120 VAC @ 38.0 A max | Dimensions (W x H x D) | 18.9 x 5.1 x 18.1" (48 x 13 x 46cm) | Weight | 70.5 lbs (32kg) | Filter Type | Bessel/Butterworth/Linkwitz-Riley 12-24-48 dB/8ve Bessel/Butterworth 18 dB/8ve | Operating Modes | Input: 2/4 Output: 4/6/8 | Crossover Frequencies | Parametric EQ (8 per Input / 9 per Output): Gain: +15 dB to -30 dB in 0.1 db steps Frequency: 19.7 Hz to 32 kHz, 136 octave steps Q/BW: 0.4 to 128 / 2.5 to 0.008 (Sections can be switched to shelving response)High and Low-pass Filters (1 of each per output): Frequency HPF: 10 Hz to 16 kHz, 1/36 octave steps Frequency LPF: 35 Hz to 22 kHz, 1/36 octave steps | Gain Range | Input: +6 dB to -40 dB in 0.1 dB steps Output: +15 dB to -40 dB in 0.1 dB steps and mute | Front Panel Switches | 12 x Mute buttons 12 x Channel edit buttons 6 x Utility buttons 3 x Rotary encoders | Inputs | Analog: 4 x XLRf Digital: Not specified by manufacturer | Outputs | Analog: 8 x XLRm Digital: Not specified by manufacturer | Maximum Input Level | Not specified by manufacturer | Maximum Output | +20 dBm into 600 ohms | Frequency Response | 20 Hz to 20 kHz, +1/2dB (-3dB @ 32kHz) | Dynamic Range | >116 dB, 20 Hz to 20 kHz unweighted | Noise | Not specified by manufacturer | Display | 2 x 24 character LCD 2 x 6 point input and 8 x6 point output meters | Dimension | 19 x 11.8 x 1.75" (482 x 300 x 45mm) | Weight | 7.3 lbs (3.3 kg) | Specialties | Program limiter and look-ahead "D-Max" limiter per output Program Limiter: Threshold: +22 dBu to -10 dBu Attack: 0.3 to 90 mSec Release: 2/4/8/16/32 x Attack time D-Max Limiter: Attack: 60 µS Release: Slow/Medium/Fast | |
The user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D can be downloaded in .pdf
format if it did not come with your new studio monitors, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Quested users keep a unique electronic library
for Quested studio monitorss,
where you can use our link to download the user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D.
The user manual lists all of the functions of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D,
all the basic and advanced features and tells you how to use the studio monitors.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Quested service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D. User manuals are also
available on the Quested website under Pro Audio - Recording - Studio Monitors.
Question and answer discussion forum concerning user instructions and resolving problems with the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D
|
|
|
|
|