PDF-MANUALS.com | User manual here!
User manual

User manual SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR

Operating instructions and pdf manual for use - SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR User manual, User manual SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR, SURGEX, SX-20NE-RT-AR, Access, Ready, Branch, Circuit,


User manual for SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR

SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR
  • Manufacturer: SURGEX
  • Basic description and contents of package
  • Product classification: Pro Audio - Power Equipment - Power Distributors & Conditioners
  • Safety instructions
  • Startup and operation of the power distributors & conditioners
  • Tips for setting up your SURGEX
  • Settings and expert assistance
  • Contact SURGEX service
  • Troubleshooting
  • Warranty information
  • Price: 849 USD
We recommend checking out our discussion threads on the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR, which address similar problems with connecting and setting up Power Distributors & Conditioners SURGEX.



User manual for the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR

The user manual for the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR provides necessary instructions for the proper use of the product Pro Audio - Power Equipment - Power Distributors & Conditioners.

The SurgeX SX-20NE-RT-AR Access Ready Branch Circuit Surge Eliminator & Power Conditioner may be used to switch up to 20A at 120V. The simple Web server structure allows basic control of one branch circuit. This network-attached, IP-addressed, Web-controlled AC surge eliminator and power conditioner features extensive programming and setup capabilities that can be accessed by a Web browser through a DMU (Device Management Utility) or a CLI (Command Line Interface).
If you own a SURGEX power distributors & conditioners and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR:
Specifications
    Load Rating 20 A @ 120 V (2,400 W)
    Power Requirement 20 W @ no load
    Certifications & Approvals UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse
    Measured suppressed voltage: 170 V, no failures
    Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
    EMI/RFI Filter, Normal Mode (50 Ω load): 40 dB at 100 kHz, 50 dB at 300 kHz, 50 dB at 3 MHz, 50 dB at 30 MHz
    EMI/RFI Filter, Common Mode (50 Ω load): 18 dB at 300 kHz, 30 dB at 1 MHz, 50 dB at 5 MHz, 50 dB at 20 MHz
    Safety Surge Let-Through Voltage (6,000 V surge): 0 V
    Maximum Applied Surge Voltage: 6,000 V
    Maximum Applied Surge Current: Unlimited, due to current limiting
    Maximum Applied Surge Energy: Unlimited, due to current limiting
    Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000
    Maximum Load Inrush Current During Power-up: 1,000 Joules

    1.2 x 50 µs pulse, industry standard combination wave surge, as per IEEE C62.41.

    Compliance UL/cUL: UL60950 Listed I.T.E., File No. E225914, UL 1449 3rd Edition In Progress
    CE: Directives 89/336/EEC, 92/31/EEC and 93/68/EEC, EN 60950 - 3rd Edition, EN55022 - 1998 Class B
    FCC Part 15 class B
    Remote Control Voltage: 5 to 30 VDC
    Control Draw Current: 5 mA maximum
    Contact Closure Resistance: 100 Ω maximum
    Auxiliary Relay Contact Rating: 30 VDC at 1 A
    Remote Turn-on Current Draw: Contact Closure - 3 mA, 5 VDC Applied Voltage - 1 mA, 12 VDC Applied Voltage: 2.5 mA, 24 VDC Applied Voltage - 5 mA
    Network Single 10/100 Unshielded Twisted Pair Ethernet Jack
    IP Addressed: DHCP Assigned or Static
    Internal HTTP Web Server
    Forms processing browser required
    Internal Telnet server
    LED Output 12 VDC, maximum 20 mA (resistor required)
    Temperature Range 41 to 95ºF (5 to 35ºC)
    Humidity Range 5 to 95% R.H., non-condensing
    Listings Agency listings - ETL and cETL (UL 1449, 2nd edition, CSA C22.2 No.8-M1986, R2000)
    Dimensions (H x W x D) 12.0 x 12.0 x 4.0" (30.5 x 30.5 x 10.2 cm)
    Weight 15.0 lb (6.8 kg)
    The user manual for the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR can be downloaded in .pdf format if it did not come with your new power distributors & conditioners, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other SURGEX users keep a unique electronic library for SURGEX power distributors & conditionerss, where you can use our link to download the user manual for the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR.

    The user manual lists all of the functions of the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR, all the basic and advanced features and tells you how to use the power distributors & conditioners. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from SURGEX service.

    If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR. User manuals are also available on the SURGEX website under Pro Audio - Power Equipment - Power Distributors & Conditioners.



    Discussion Question and answer discussion forum concerning user instructions and resolving problems with the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR - no comments have been made yet - be the first to add a comment

    Post new comment/question/response regarding the SURGEX SX-20NE-RT-AR Access Ready Branch Circuit SX20NERTAR

    Fields marked with * must be filled out.
    Your name *:
    E-mail :
    Subject *:
    Message text *:
    Enter the code *:
    (spam block)
    "manual"
    If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

     

    Can't find what you're looking for? Try Google Search!



    Current discussions
    Most recently discussed products:

    Simmons 6-24x50 - Simmons 6-24x50 Predator Varmint Riflescope 656245
    Posted by: Stuart Williams
    2024-03-26 12:36:48

    I have located manual for this on your site but how do I download / print it please ?...
    USER MANUAL TSP2 17 BUN - Telmax TSP2-17-BUN Dual 17" Presidential TSP2-17BUN
    Posted by: AYO
    2024-03-26 10:07:35

    MANUAL REQUIRED TO SET UP...
    lens servo - Fujinon ESM-15A-SA Digital Servo Unit for Fujinon ESM-15A-SA
    Posted by: julia yoko
    2024-03-25 22:07:20

    i would like to know where the lens manual can be found...
    NEPVS14-17 - ITT Night Enforcer PVS-14 Pinnacle Night Vision ITTE-NEPVS14-17
    Posted by: Keller Bradshaw
    2024-03-25 17:57:35

    Hi, I would like a user manual for the NEPVS14-17...
    YS 03 above water - Sea & Sea YS-03 Universal Lighting System SS-03541
    Posted by: sameer
    2024-03-24 22:26:52

    Hello Would like to know is it safe to use YS 03 strobe outside water for practice purpose ? Regards...

    Uploaded instruction manuals
    Upload a link to an instruction manual for a depicted product here:

    Link format "http://www.link2manual.com/manual.pdf"

    Enter the code: "manual"






    PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
    sitemap.txt alx