|
User manual for Symetrix Solus 4 SymNet DSP Hardware SOLUS 4
- Manufacturer: Symetrix
- Basic description and contents of package
- Product classification: Pro Audio - Installation Sound - Networked Audio Systems
- Safety instructions
- Startup and operation of the networked audio systems
- Tips for setting up your Symetrix
- Settings and expert assistance
- Contact Symetrix service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4,
which address similar problems with connecting and setting up Networked Audio Systems Symetrix.
|
User manual for the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4
The user manual for the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4 provides
necessary instructions for the proper use of the product Pro Audio - Installation Sound - Networked Audio Systems.
The Symetrix Solus 4 SymNet DSP Hardware is essentially a core audio routing, control logic and DSP processing matrix for fixed installation in commercial sound reinforcement applications, paging systems, background audio systems, professional sound reinforcement and more. The solus 4 features 4 mic/line inputs with phantom power and 4 outputs.
|
If you own a Symetrix networked audio systems and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4 in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4:
Inputs | Number of inputs: 4 switchable balanced mic or line level on Solus 4. Connectors: 3.81mm terminal blocks Nominal input level: +4dBu line or -36dBu mic level (software selectable) with 20dB of headroom. Mic Pre-amp gain: +40dB Input trim: +/- 24dB Maximum input level: +23dBu Input impedance: > 18 kΩ balanced, > 9 kΩ unbalanced, > 2 kΩ with phantom power engaged. CMRR: > 50dB @ 1kHz, unity gain. Mic Pre-amp EIN: < -125dBu, 22Hz - 22kHz, 100 Ω source impedance. Phantom Power: +20VDC, 20mA maximum per input. | Outputs | Number of outputs: 4 line level on Solus 4 Connectors: 3.81mm terminal blocksNominal output level: +4dBu line level with 20dB of headroom. For unbalanced analog output, do not connect the minus output terminal. Unbalanced configuration results in 6 dB lower output level. Maximum output level: +24dBuOutput impedance: 200 Ω balanced, 100 Ω unbalanced | Sample Rate | 48kHz | Frequency Response | 20Hz - 20kHz, +/- 0.5dB | Dynamic Range | > 110dB (A-Weighted), input to output. | THD | < -85dB (un-weighted); 1kHz @ +22 dBu with 0dB gain | Crosstalk | < -90 dB @ 1 kHz, typical | Latency | < 1.6ms, input routed to output | Power | 100-240 VAC, 50/60 Hz, 25 Watts maximum. Universal input. | Ventilation | Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08cm, 2" minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc. | Dimensions (WxDxH) | 18.91 x 7.5 x 1.72" (48.02 x 19.05 x 4.37cm) 1 Rack Unit | Weight | 8 lb (3.63kg) | Package Weight | 7.65 lb | Box Dimensions (LxWxH) | 25.5 x 16.5 x 3.5" | |
The user manual for the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4 can be downloaded in .pdf
format if it did not come with your new networked audio systems, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Symetrix users keep a unique electronic library
for Symetrix networked audio systemss,
where you can use our link to download the user manual for the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4.
The user manual lists all of the functions of the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4,
all the basic and advanced features and tells you how to use the networked audio systems.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Symetrix service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4. User manuals are also
available on the Symetrix website under Pro Audio - Installation Sound - Networked Audio Systems.
Question and answer discussion forum concerning user instructions and resolving problems with the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4 - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Symetrix Solus 4 SymNet DSP Hardware SOLUS 4
|
|
|
|
|