PDF-MANUALS.com | User manual here!
User manual

User manual Ashly nXp1.54 Network Power Amplifier NXP1.54

Operating instructions and pdf manual for use - Ashly nXp1.54 Network Power Amplifier NXP1.54 User manual, User manual Ashly nXp1.54 Network Power Amplifier NXP1.54, Ashly, nXp1.54, Network, Power, Amplifier, NXP1.54, Video


User manual for Ashly nXp1.54 Network Power Amplifier NXP1.54

Ashly  nXp1.54 Network Power Amplifier NXP1.54
  • Manufacturer: Ashly
  • Basic description and contents of package
  • Product classification: Pro Audio - Installation Sound - 70-Volt Amplifiers
  • Safety instructions
  • Startup and operation of the 70-volt amplifiers
  • Tips for setting up your Ashly
  • Settings and expert assistance
  • Contact Ashly service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the Ashly nXp1.54 Network Power Amplifier NXP1.54, which address similar problems with connecting and setting up 70-Volt Amplifiers Ashly.



User manual for the Ashly nXp1.54 Network Power Amplifier NXP1.54

The user manual for the Ashly nXp1.54 Network Power Amplifier NXP1.54 provides necessary instructions for the proper use of the product Pro Audio - Installation Sound - 70-Volt Amplifiers.

The nXp1.54 Network Power Amplifier from Ashly Audio is the networkable version of the nX amplifier. It comes with Ethernet control, serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability. All these are controlled using Ashly Audio's Protea software suite. This amplifier is designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces, and convention centers.
If you own a Ashly 70-volt amplifiers and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Ashly nXp1.54 Network Power Amplifier NXP1.54 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Ashly nXp1.54 Network Power Amplifier NXP1.54:
Specifications
    General
    Voltage Gain Selectable at 26 dB, 32 dB, 38 dB, or 1.4 V

    0 dBu = 0.775 VRMS

    Damping Factor >250 (8 Ω load <1 kHz)
    Filter Input High Pass Filter: 80 Hz 2nd order
    Distortion <0.5% SMPTE, typical
    <0.5% THD-N, typical (8 Ω, 10 dB below rated power, 20 Hz to 20 kHz)
    Channel Separation -75 dB (dB from full output, 1 kHz)
    Signal / Noise 20 Hz to 20 kHz, un-weighted
    >114 dB (all 3.0x models)
    Frequency Response 20 Hz to 20 kHz, ±0.05 dB
    Connector Balanced Input Connector: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
    Input Impedance 10 kΩ
    Maximum Input Level +21 dBu
    Speaker Output Connector: Neutrik & speakON
    Network Control Network: Compatible with standard 100 MB Ethernet
    AUX Outputs Connector: Balanced Euroblock 3.5 mm
    Maximum Output: 21 dBu
    Contact Closure Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode
    Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
    Data Data Connection: Euroblock 3.5 mm - Gnd, +18 V, In, Out
    Level Control Remote DC: Euroblock 3.5 mm - Gnd, CV, V+ per input
    Attenuation Front panel, software, offset link group, and remote per channel
    fully off = mute
    Amplifier Amplifier Protection: Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
    Cooling Continuously variable temperature controlled axial fan(s)
    Environmental Non-condensing 32 to 113ºF (0 to 45ºC)
    Power Requirements
    Power At 50 Hz
    Nominal (Automatic Sensing SMPS): 120 VAC
    Operating Range: 70 to 135 VAC
    Minimum Power-Up: 85 VAC

    At 60 Hz
    Nominal (Automatic Sensing SMPS): 240 VAC
    Operating Range: 140 to 270 VAC
    Minimum Power-Up: 170 VAC
    Connector Power Cable Connector: 20 A powerCON
    Output For Maximum Output Power Per Channel, EIAJ Test Standard, 1 kHz, 20 Hz to 20 kHz, 1% THD & Low Z Output:

    2 Ω: 1,500 W
    4 Ω: 1,500 W
    8 Ω: 1,250 W

    For Low Z output, Bridge Mode, 20 Hz to 20 kHz & 1% THD:
    4 Ω: 3,000 W

    For Output Per Channel:
    70 V: 1,500 W
    100 V: 1,250 W

    All Channels Driven

    Power Draw Sleep Mode: < 1 W
    Standby Mode: 70 W
    Idle (No Signal): 100 W

    All Channels Driven

    Current Draw For 120 VAC
    Sleep Mode: 0.1 A
    Standby Mode: 1.30 A
    Idle (No Signal): 1.85 A

    For 240 VAC
    Sleep Mode: 0.05 A
    Standby Mode: 0.65 A
    Idle (No Signal): 0.93 A
     

    Maximum for all Channels Driven:
     

    For 120 VAC
    Typical: 16.0 A
     

    For 240 VAC
    Typical: 8.0 A

    Dissipation Thermal Dissipation: <br> Sleep Mode: <3.4 BTU/hr <br>
    Standby Mode: 238 BTU/hr<br>

    Idle (no signal): 340 BTU/hr<br>

    Typical (1 / 8 Max Power): 1,700 BTU/hr

    All Channels Driven

    LED Indicators Front Panel LED Indicators: White LED:
    Power Switch: On, off, standby (flashing)

    Red LED:
    Clip / Mute Per Channel: Clip @ 1 dB below full output / mute
    Protect: On, Off

    Green LED:
    Signal Per Channel: -18 dBu
    Bridge Per Channel Pair: On, off
    Com: On, for Ethernet data or device ID
    Current Per Channel: Proportional to output

    Yellow LED:
    Temperature Per Channel: On dim at 90% max operating temperature, full bright + protect at 100%
    Sleep: On, amplifier is asleep from audio inactivity
    Disable: On, power switch & front panel attenuators are disabled
    Processor
    Input Source Protēa DSP
    Options: Analog, auto (net, AES3, analog) Note: All DSP functions can be linked to 1 of 16 link groups
    Limiter Brick Wall Limiter: Threshold: -20 to 20 dBu
    Ratio: Infinite
    Attack: 0.2 to 50 ms/dB
    Release: 5 to 1000 ms/dB
    Control Advanced Gate Controls: Key Engage Enable: Yes
    Key Frequency: 20 Hz to 20 kHz
    Key Bandwidth: 0.016 to 3.995 octave
    Gain Gain (with / without VCA): -50 to 12 dB, off, polarity invert
    Digital VCA Groups: 4 available
    Remote RD8C Gain: Enable per channel, 0 dB to -∞
    WR-5 (neWR-5) Remote Gain: 0 to -50 dB, mute
    EQ Type For 31-Band
    Filter Type: Constant Q or proportional
    Bandwidth: 0.499 octave to 0.25 octave

    For Parametric 2,4,6, or 10 Band
    Frequency: 20 to 20 kHz
    Level: -30 to 15 dB
    Q Value: 0.016 to 3.995 octave
    For Hi / Low Shelf 6 / 12 dB/octave
    Frequency: 20 Hz to 20 kHz
    Level: -15 to 15 dB

    For All Pass
    Frequency: 20 Hz to 20 kHz

    For Variable Q HP / LP
    Frequency: 20 Hz to 20 kHz
    Q Value: 3.047 to 0.267

    For Notch / Bandpass
    Frequency: 20 Hz to 20 kHz
    Q Value: 92.436 to 0.267
    Crossover 2 Way, 3 Way, 4 Way Crossover & High Pass / Low Pass Filters
    Bessel & Butterworth Filters: 12 / 18 / 24 / 48 dB/octave
    Linkwitz-Riley Filter: 12 / 24 / 48 dB / octave
    Frequency: Off, 20 Hz to 20 kHz
    Delay Sampling Rate: At 48kHz (Input Time, Distance & Temperature)
    Speaker Delay: 0 to 21 ms
    Delay: 0 to 682 ms At 96 kHz (Input Time, Distance & Temperature)
    Speaker Delay: 0 to 10.6 ms
    Delay: 0 to 341 ms
    Audio Metering Range: -60 to 20 dBu
    Increments: 1 dB
    Peak Hold Indicator: Yes
    Signal Generator Pink Noise, White Noise, Sine Wave
    Signal Level: Off, -50 to 20 dBu
    Sine Wave Frequency: 20 Hz to12 kHz
    Processor Input A/D, Output D/A: 24 bit
    DSP Processors: 32-bit floating point
    Sample Rates: 48 kHz, 96 kHz
    Propagation Delay @ 48 kHz: 1.42 ms
    Propagation Delay @ 96 kHz: 0.71 ms
    Mixer Gain (0.5 dB Increments): Off, -50 to 12dB
    Mute: Per channel
    Auto-mixer Enabled: Per channel
    Global Auto-mixer Response: 0.01 to 2 sec
    Enable Ducking at Mixer: Yes
    Ducking LED: Per channel if enabled Metering: Level, auto-mixer level
    Filters Number: 12 In/Out per filter: Yes
    Lock per filter and global lock: Yes
    Filter Modes: Float, Restricted, Manual
    Filter Type: Notch, Parametric
    Filter Frequency Range: 20 Hz to 20 kHz
    Notch Filter: -∞
    Parametric Filter: 15 dB to -30 dB
    Filter Bandwidth: 0.016 to 3.995 octave
    Detector Sensitivity: 5 levels
    Float Time: 5 minutes to 24 hours

    Only available with 48 kHz sampling rate

    Compressor
    Threshold -20 to 20 dBu
    Ratio 1.2:1 to infinite
    Attack 0.2 to 50 ms
    Release 5 to 1000 ms/dB
    Detectors Peak / average
    Attenuation 2 available
    Metering In, out, attenuation, graphical
    Controls
    Level Target Level: -40 to 20 dBu
    Action Type Gentle, normal, aggressive, user defined
    Maximum Gain 0 to 22 dB
    Metering Input, gain, attenuation
    Ratio 1.2:1 to 10:1
    Threshold -30 to 0 dB
    Gain 5 to 1000 ms/dB
    Hold 0 to 6 seconds
    Noise Characteristics
    Gain Maximum: -20 to 20 dB
    Minimum Base: -40 to 20 dB
    Gain Adjustment Range 0.2 to 20 s/dB
    Groups Link Groups: 16 available
    Input Channels ANC: 1 to 2 or 1 to 4
    Threshold Range Noise: -40 to 20 dBu
    Ratio Program/Ambient Gain: 0.3:1 to 3:1
    Metering Input level, attenuation, average noise
    Ducking Trigger Threshold: -80 to 20 dBu
    Ducking Release: 5 to 1000 ms/dB
    Ducking Depth: 0 to -30 dB, -∞
    Enable Ducking at Matrix Mixer: Yes
    Metering: Input
    Gate
    Threshold -80 to 20 dBu
    Range Off, 100 to 0 dB
    Attack 0.2 to 50 ms/dB
    Release 5 to 1000 ms/dB
    Metering Key signal, gate LED, graphical
    Dimensions (W x H x D) 19.0 x 3.5 x 16.8" (482.6 x 89.0 x 426.7 mm)
    Weight < 28.0 lb (12.7 kg)
    Packaging Info
    Package Weight 28.0 lb
    Box Dimensions (LxWxH) 19.0 x 16.0 x 4.0"
    The user manual for the Ashly nXp1.54 Network Power Amplifier NXP1.54 can be downloaded in .pdf format if it did not come with your new 70-volt amplifiers, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Ashly users keep a unique electronic library for Ashly 70-volt amplifierss, where you can use our link to download the user manual for the Ashly nXp1.54 Network Power Amplifier NXP1.54.

    The user manual lists all of the functions of the Ashly nXp1.54 Network Power Amplifier NXP1.54, all the basic and advanced features and tells you how to use the 70-volt amplifiers. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Ashly service.

    If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Ashly nXp1.54 Network Power Amplifier NXP1.54. User manuals are also available on the Ashly website under Pro Audio - Installation Sound - 70-Volt Amplifiers.



    Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Ashly nXp1.54 Network Power Amplifier NXP1.54 - no comments have been made yet - be the first to add a comment

    Post new comment/question/response regarding the Ashly nXp1.54 Network Power Amplifier NXP1.54

    Fields marked with * must be filled out.
    Your name *:
    E-mail :
    Subject *:
    Message text *:
    Enter the code *:
    (spam block)
    "manual"
    If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

     

    Can't find what you're looking for? Try Google Search!



    Current discussions
    Most recently discussed products:

    Redfield 3-9X40 Accu Range - Redfield 3-9x40 Revolution Riflescope (Accu-Range) 67095
    Posted by: CHARLES MIKULA
    2024-04-26 00:49:10

    I lost my Redfield owners manual in a recent move from Virginia to Florida! Can I receive a replacement?...
    Input Power - Gemini XGA-3000 Professional Power Amplifier XGA-3000
    Posted by: Brent
    2024-04-25 22:33:49

    What is the input power requirements? Or better yet, what is the size fuse (in amps) that is listed as a 5mmx20mm?...
    User Manual - Odyssey Innovative Designs FZ1316WDLXII Flight FZ1316WDLX-II
    Posted by: Mike McGrath
    2024-04-25 18:51:37

    Please send me the user manual for Odyssey FR1316WDLX. Thanks!...
    MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
    Posted by: Jae Gil, Ha
    2024-04-25 09:48:07

    needs manual file...
    Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
    Posted by: Judy Whiteley
    2024-04-24 16:51:27

    Please send user’s manual in normal size print...

    Uploaded instruction manuals
    Upload a link to an instruction manual for a depicted product here:

    Link format "http://www.link2manual.com/manual.pdf"

    Enter the code: "manual"






    PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
    sitemap.txt alx