User manual Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100
Operating instructions and pdf manual for use - Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100 User manual, User manual Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100, Benchmark, AHB2, High-Resolution, Power, Amplifier,
User manual for Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100
Manufacturer: Benchmark
Basic description and contents of package
Product classification: Pro Audio - Live Sound - Power Amplifiers
Safety instructions
Startup and operation of the power amplifiers
Tips for setting up your Benchmark
Settings and expert assistance
Contact Benchmark service
Troubleshooting
Warranty information
Click to enlarge image
We recommend checking out our discussion threads on the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100,
which address similar problems with connecting and setting up Power Amplifiers Benchmark.
User manual for the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100
The user manual for the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100 provides
necessary instructions for the proper use of the product Pro Audio - Live Sound - Power Amplifiers.
The silver AHB2 High-Resolution Power Amplifier from Benchmark is designed to accurately reproduce high resolution audio. The dynamic range approaches 130 dB, and the frequency response extends below 0.1 Hz and beyond 200 kHz. When reproducing high-resolution 24-bit PCM and 1-bit DSD digital audio formats, this amplifier allows you to hear nuances and dynamics which get lost when using amplifiers with lower dynamic ranges.
The AHB2 has bi-polar class-AB output stage that delivers high output current and low noise. The THX patented feed-forward error correction provides accurate cancellation of zero-crossing errors. In addition, the AHB2 uses a resonant switching power supply with a fast control loop so mechanical hum is eliminated while magnetic field strength is reduced.
If you own a Benchmark power amplifiers and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100 in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100:
Output Power
1 kHz, < 0.0003% THD+N 100 W/channel into 8 Ω, both channels driven 130 W/channel into 6 Ω, both channels driven 190 W/channel into 4 Ω, both channels driven 240 W/channel into 3 Ω, both channels driven 200 W Bridged Mono into 16 Ω 380 W Bridged Mono into 8 Ω 480 W Bridged Mono into 6 Ω
Use Mid-Gain or High-Gain settings for unbalanced inputs. Unbalanced inputs require RCA to XLRM adapter cables.
Input Impedance
50 kΩ, normal mode 1 MΩ, common mode
Triggers
12 VDC, 200 mA current-limited output of remote device VIL: 1.26 V, VIH: 2.7 V (input responds to 3.3 V logic and higher)
Input Voltage Range
-0.3 to 30 VDC
Input Impedance
20 kΩ
Cross Talk
Better than -115 dB at 1 kHz Better than -92 dB at 20 kHz
Frequency Response
Better than 0.1 Hz to 200 kHz, +0/-3 dB -0.01 dB at 20 Hz, -0.17 dB at 20 kHz, 8Ω Load -0.23 dB at 20 Hz, -0.32 dB at 20 kHz, 4Ω Load
Input CMRR
80 dB at 20 Hz, typical 80 dB at 1 kHz, typical 65 dB at 20 kHz, typical
Maximum Output Current
18 A per channel, both channels driven 18 A protection shut-down threshold
Signal-to-Noise Ratio
132 dB A-weighted, Stereo Mode 135 dB A-weighted, Bridged Mono 130 dB Unweighted, 20 Hz to 20 kHz, Stereo Mode 133 dB Unweighted, 20 Hz to 20 kHz, Bridged Mono
THD+N
1 kHz, 80 kHz LPF, at full rated output into any rated load Stereo Mode: < -118 dB (< 0.00013%) Mono Mode: < -118 dB (< 0.00013%)
THD
1 kHz, 20 kHz LPF, at full rated output into any rated load Stereo Mode: < -119 dB (< 0.00011%) Mono Mode: < -120 dB (< 0.00010%)
Cooling
Passive heat sinks
Power Requirements
100 to 120 VAC ± 10%, 8 A, 50 - 60 Hz 220 to 240 VAC ± 10%, 8 A, 50 - 60 Hz
Dimensions (W x H x D)
11.0 x 3.9 x 9.3" (28.0 x 9.9 x 23.7 cm) including feet and binding posts
Weight
12.5 lb (5.7 kg)
The user manual for the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100 can be downloaded in .pdf
format if it did not come with your new power amplifiers, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Benchmark users keep a unique electronic library
for Benchmark power amplifierss,
where you can use our link to download the user manual for the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100.
The user manual lists all of the functions of the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100,
all the basic and advanced features and tells you how to use the power amplifiers.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Benchmark service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100. User manuals are also
available on the Benchmark website under Pro Audio - Live Sound - Power Amplifiers.
Question and answer discussion forum concerning user instructions and resolving problems with the Benchmark AHB2 High-Resolution Power Amplifier 500-18000-100 - no comments have been made yet - be the first to add a comment
Why is the blue light (wireless symbol)...what is it on...its a blue light. I have had these for years and have never had that light come on and it is not allowing me to print! What do I do to turn it off? ...K&M manual - K&M 200 Telescoping Microphone Stand (Black) 20000-500-55 Posted by: jpdaval69 2024-09-10 00:50:11
I need the service manual/schematic of Universal Audio Solo/610 Serial number: 2310 MfgDt: 0607.
I hope you have it and I'm willing to be charged for it.
Best Regards....True Dock not recognizing hard drives - Kingwin True Dock Super-Speed USB 3.0 to TD-2535U3 Posted by: bf1955 2024-08-22 15:34:26
True Dock is not recognizing HDD, the HDD light does not come on, even though the power light does come one....