PDF-MANUALS.com | User manual here!
User manual

User manual Interfit EXD400 Digital Flash Head (110V AC) INT490

Operating instructions and pdf manual for use - Interfit EXD400 Digital Flash Head (110V AC) INT490 User manual, User manual Interfit EXD400 Digital Flash Head (110V AC) INT490, Interfit, EXD400, Digital, Flash, Head, 110V, AC, INT490,


User manual for Interfit EXD400 Digital Flash Head (110V AC) INT490

Overall rating 4.0
Overall Rating: 4.0

80% of respondents would recommend this to a friend.
Interfit EXD400 Digital Flash Head (110V AC) INT490
  • Manufacturer: Interfit
  • Basic description and contents of package
  • Product classification: Lighting & Studio - Strobe Lighting - Monolights
  • Safety instructions
  • Startup and operation of the monolights
  • Tips for setting up your Interfit
  • Settings and expert assistance
  • Contact Interfit service
  • Troubleshooting
  • Warranty information
  • Price: 226 USD
We recommend checking out our discussion threads on the Interfit EXD400 Digital Flash Head (110V AC) INT490, which address similar problems with connecting and setting up Monolights Interfit.



User manual for the Interfit EXD400 Digital Flash Head (110V AC) INT490

The user manual for the Interfit EXD400 Digital Flash Head (110V AC) INT490 provides necessary instructions for the proper use of the product Lighting & Studio - Strobe Lighting - Monolights.

The Interfit EXD400 Digital Flash Head (110V AC) is another step forward in the evolution of the EX flash system.  The lightweight, economical monolight gives you a total of 400W/s of power, with precise power adjustment in 1/10 f-stop increments and a 6 f-stop range, providing excellent control over your lighting. Fan-cooling extends the life of both the 100W modeling light and the user-replaceable flash tube.  A built-in slave cell responds to flash or to the optional infrared transmitter, and audible and visible signals alert you when the flash is fully recycled. It even has a program that overcomes the problem of pre-exposure flash from a camera setting off your flashes prematurely. The EXD400’s Auto-Dump feature discharges extra power in the capacitors, the second you turn down the power. The EXD400 comes with an umbrella reflector, built-in ergonomic handle and a flash tube transport cover.  
If you own a Interfit monolights and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Interfit EXD400 Digital Flash Head (110V AC) INT490 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
User manual for Interfit EXD400 Digital Flash Head (110V AC) INT490Download user manual for Interfit EXD400 Digital Flash Head (110V AC) INT490
(PDF file, 0.61 MB)
Additional parameters of the Interfit EXD400 Digital Flash Head (110V AC) INT490:
Specifications
    Maximum Watt/Seconds 400W/s
    Guide Number 196' (60 m) @ ISO 100
    Color Temperature 5600K +/- 200K
    Recycle Time 1.5 seconds
    Flash Duration Not specified by manufacturer
    Flash Variability 6 stops: full to 1/32 power
    User Replaceable Flashtube Yes
    Changeable Reflector Yes
    Modeling Light Wattage 100W, proportionate, on, off
    Flash Ready Indicator Yes, audible and visible
    Operating Voltage 110V AC
    Built-in Slave Cell Yes, optical
    Range 30' (10 m)
    Sync Line Voltage 5V
    Power Requirements 110V AC
    Circuit Protection Yes, 6.3A fuse
    Fan Cooled Yes
    Auto Dump Yes
    Dimensions Head with reflector: 10.5 x 8.0 x 5.0" (266.7 x 203 x 127 cm)
    Weight 5.0 lb (2.26 kg)
    Packaging Info
    Package Weight 7.4 lb
    Box Dimensions (LxWxH) 17.7 x 10.3 x 10.2"
    The user manual for the Interfit EXD400 Digital Flash Head (110V AC) INT490 can be downloaded in .pdf format if it did not come with your new monolights, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Interfit users keep a unique electronic library for Interfit monolightss, where you can use our link to download the user manual for the Interfit EXD400 Digital Flash Head (110V AC) INT490.

    The user manual lists all of the functions of the Interfit EXD400 Digital Flash Head (110V AC) INT490, all the basic and advanced features and tells you how to use the monolights. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Interfit service.

    If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Interfit EXD400 Digital Flash Head (110V AC) INT490. User manuals are also available on the Interfit website under Lighting & Studio - Strobe Lighting - Monolights.



    Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Interfit EXD400 Digital Flash Head (110V AC) INT490 - no comments have been made yet - be the first to add a comment

    Post new comment/question/response regarding the Interfit EXD400 Digital Flash Head (110V AC) INT490

    Fields marked with * must be filled out.
    Your name *:
    E-mail :
    Subject *:
    Message text *:
    Enter the code *:
    (spam block)
    "manual"
    If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

     

    Can't find what you're looking for? Try Google Search!



    Current discussions
    Most recently discussed products:

    Redfield 3-9X40 Accu Range - Redfield 3-9x40 Revolution Riflescope (Accu-Range) 67095
    Posted by: CHARLES MIKULA
    2024-04-26 00:49:10

    I lost my Redfield owners manual in a recent move from Virginia to Florida! Can I receive a replacement?...
    Input Power - Gemini XGA-3000 Professional Power Amplifier XGA-3000
    Posted by: Brent
    2024-04-25 22:33:49

    What is the input power requirements? Or better yet, what is the size fuse (in amps) that is listed as a 5mmx20mm?...
    User Manual - Odyssey Innovative Designs FZ1316WDLXII Flight FZ1316WDLX-II
    Posted by: Mike McGrath
    2024-04-25 18:51:37

    Please send me the user manual for Odyssey FR1316WDLX. Thanks!...
    MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
    Posted by: Jae Gil, Ha
    2024-04-25 09:48:07

    needs manual file...
    Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
    Posted by: Judy Whiteley
    2024-04-24 16:51:27

    Please send user’s manual in normal size print...

    Uploaded instruction manuals
    Upload a link to an instruction manual for a depicted product here:

    Link format "http://www.link2manual.com/manual.pdf"

    Enter the code: "manual"






    PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
    sitemap.txt alx