PDF-MANUALS.com | User manual here!
User manual

User manual Quested Q412D Active 3-Way Monitoring System with Amp and Q412D

Operating instructions and pdf manual for use - Quested Q412D Active 3-Way Monitoring System with Amp and Q412D User manual, User manual Quested Q412D Active 3-Way Monitoring System with Amp and Q412D, Quested, Q412D, Active, 3-Way, Monitoring, Sys


User manual for Quested Q412D Active 3-Way Monitoring System with Amp and Q412D

Quested Q412D Active 3-Way Monitoring System with Amp and Q412D
  • Manufacturer: Quested
  • Basic description and contents of package
  • Product classification: Pro Audio - Recording - Studio Monitors
  • Safety instructions
  • Startup and operation of the studio monitors
  • Tips for setting up your Quested
  • Settings and expert assistance
  • Contact Quested service
  • Troubleshooting
  • Warranty information
  • Price: 41 USD
We recommend checking out our discussion threads on the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D, which address similar problems with connecting and setting up Studio Monitors Quested.



User manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D

The user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D provides necessary instructions for the proper use of the product Pro Audio - Recording - Studio Monitors.

The Q412D Monitoring System from Quested includes a three-way active speaker designed to be soffit-mounted main monitors for large control rooms. The system comprises four 12" low frequency drivers, one 3" mid frequency driver, and one 1.5" high frequency driver that combine to provide effortless and articulate performance with sound pressure levels of 130 dB.
If you own a Quested studio monitors and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D:
Q412D
Driver Bass: 4 x 12" / 30.5 cm
Mid: 3" / 7.5 cm
High: 1.5" / 3.7 cm
Maximum SPL 130 dB at 1 m
Frequency Response 20 Hz to 20 kHz ±2 dB
Input Connections Gold Plated Binding Post: 3 x twin pair
Accepts 0.2" / 0.4 cm banana plugs or bare wires
Amplifier (Power) Bass: 1850 W (RMS) into 2 ohms
Mid: 450 W (RMS) into 8 ohms
High 450: 450 W (RMS) into 8 ohms
Crossover Point Low: 450 HZ Linkwitz-Riley 24 dB/oct
High: 4.5 kHz Linkwitz-Riley 24 dB/oct
Dimensions (W x H x D) 37.0 x 34.6 x 26.4" / 94.0 x 88.0 x 67.0 cm
Weight 286.6 lb / 130.0 kg
AP800
Power Rating 450 W into 8 ohms
770 W into 4 ohms
Damping Factor 400 @ 8 ohms 1 kHz
Input Sensitivity +7 dBm
Input Impedance 10 kOhms
Gain 33 dB
Frequency Response 20 Hz to 20 kHz
Signal to Noise Ratio Not specified by manufacturer
Total Harmonic Distortion (THD) 0.005%
Input Connections 3-pin XLR
Output Connectors Shrouded Binding Posts: 4 mm
Controls Front Panel On/Off, rotary potentiometers, mute
Controls Rear Panel 2/4 or 4/8 switch, stereo or bridged switch
Indicators Peak meters, mute, fault/DC & limit, bridged, power, temperature
Cooling Temperature warnings and 2 fans to assist
Power Consumption Not specified by manufacturer
Power Requirements 230 VAC @ 10 A max
120 VAC @ 20 A max
Dimensions 19 x 1.75 x 15" (48.2 x 8.8 x 38.1cm)
Weight 51 lbs (23kg)
AP1300
Power Rating Watts RMS per channel
16 ohms: 400
8 ohms: 750
4 ohms: 1250
3 ohms: 1600
2 ohms:  1800
Damping Factor 1 kHz, 8 ohms
Input Sensitivity 80 dB
Input Impedance 10 kOhms
Gain 33 dB
Frequency Response 20 Hz to 20 kHz
Signal to Noise Ratio Not specified by manufacturer
Total Harmonic Distortion (THD) 0.008%
Input Connectors 3-pin XLR
Output Connectors Shrouded Binding Posts: 4 mm
Controls Front Panel Level controls, mute, link switch, signal limiters, temperature
Controls Rear Panel 2 ohm and bridged LEDs
Indicators Level indicators, fault indicators, clip warning, 2 ohms, and bridged LEDs
Cooling Cooling fans and temperature controls
Power Consumption Not specified by manufacturer
Power Requirements 230 VAC @ 20.0 A max
120 VAC @ 38.0 A max
Dimensions (W x H x D) 18.9 x 5.1 x 18.1" (48 x 13 x 46cm)
Weight 70.5 lbs (32kg)
SM-748
Filter Type Bessel/Butterworth/Linkwitz-Riley 12-24-48 dB/8ve
Bessel/Butterworth 18 dB/8ve
Operating Modes Input: 2/4
Output: 4/6/8
Crossover Frequencies Parametric EQ (8 per Input / 9 per Output):
Gain: +15 dB to -30 dB in 0.1 db steps
Frequency: 19.7 Hz to 32 kHz, 136 octave steps
Q/BW: 0.4 to 128 / 2.5 to 0.008
(Sections can be switched to shelving response)

High and Low-pass Filters (1 of each per output):
Frequency HPF: 10 Hz to 16 kHz, 1/36 octave steps
Frequency LPF: 35 Hz to 22 kHz, 1/36 octave steps

Gain Range Input: +6 dB to -40 dB in 0.1 dB steps
Output: +15 dB to -40 dB in 0.1 dB steps and mute
Front Panel Switches 12 x Mute buttons
12 x Channel edit buttons
6 x Utility buttons
3 x Rotary encoders
Inputs Analog: 4 x XLRf
Digital: Not specified by manufacturer
Outputs Analog: 8 x XLRm
Digital: Not specified by manufacturer
Maximum Input Level Not specified by manufacturer
Maximum Output +20 dBm into 600 ohms
Frequency Response 20 Hz to 20 kHz, +1/2dB (-3dB @ 32kHz)
Dynamic Range >116 dB, 20 Hz to 20 kHz unweighted
Noise Not specified by manufacturer
Display 2 x 24 character LCD
2 x 6 point input and 8 x6 point output meters
Dimension 19 x 11.8 x 1.75" (482 x 300 x 45mm)
Weight 7.3 lbs (3.3 kg)
Specialties Program limiter and look-ahead "D-Max" limiter per output

Program Limiter:
Threshold: +22 dBu to -10 dBu
Attack: 0.3 to 90 mSec
Release: 2/4/8/16/32 x Attack time

D-Max Limiter:
Attack: 60 µS
Release: Slow/Medium/Fast

 

The user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D can be downloaded in .pdf format if it did not come with your new studio monitors, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Quested users keep a unique electronic library for Quested studio monitorss, where you can use our link to download the user manual for the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D.

The user manual lists all of the functions of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D, all the basic and advanced features and tells you how to use the studio monitors. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Quested service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D. User manuals are also available on the Quested website under Pro Audio - Recording - Studio Monitors.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the Quested Q412D Active 3-Way Monitoring System with Amp and Q412D

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

Redfield 3-9X40 Accu Range - Redfield 3-9x40 Revolution Riflescope (Accu-Range) 67095
Posted by: CHARLES MIKULA
2024-04-26 00:49:10

I lost my Redfield owners manual in a recent move from Virginia to Florida! Can I receive a replacement?...
Input Power - Gemini XGA-3000 Professional Power Amplifier XGA-3000
Posted by: Brent
2024-04-25 22:33:49

What is the input power requirements? Or better yet, what is the size fuse (in amps) that is listed as a 5mmx20mm?...
User Manual - Odyssey Innovative Designs FZ1316WDLXII Flight FZ1316WDLX-II
Posted by: Mike McGrath
2024-04-25 18:51:37

Please send me the user manual for Odyssey FR1316WDLX. Thanks!...
MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
Posted by: Jae Gil, Ha
2024-04-25 09:48:07

needs manual file...
Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
Posted by: Judy Whiteley
2024-04-24 16:51:27

Please send user’s manual in normal size print...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx