|
User manual for RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M
- Manufacturer: RDL
- Basic description and contents of package
- Product classification: Pro Audio - Installation Sound - Switchers & Controllers
- Safety instructions
- Startup and operation of the switchers & controllers
- Tips for setting up your RDL
- Settings and expert assistance
- Contact RDL service
- Troubleshooting
- Warranty information
- Price: 215 USD
|
We recommend checking out our discussion threads on the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M,
which address similar problems with connecting and setting up Switchers & Controllers RDL.
|
User manual for the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M
The user manual for the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M provides
necessary instructions for the proper use of the product Pro Audio - Installation Sound - Switchers & Controllers.
The white D-RLC10M Remote Level Control with Muting, Rotary from RDL is a rotary remote level control with pushbutton muting that provides you adjustment at single or multiple locations. Optical encoder technology allows continuous knob rotation with a comfortable adjustment rate and long-term trouble-free and noise-free operation. These controls directly connect to any RDL VCA and OEM equipment with 0 to 10 Vdc ramp inputs.
A single D-RLC10M may be connected to a ramp-controlled VCA using a single-pair shielded audio cable or unshielded cable. A rear-panel switch configures the control as the MASTER. The MASTER mode causes this control to drive the 0 to 10 Vdc ramp output and to monitor its pulse terminals in case any other -RLC10M controls are connected. As many as nine additional -RLC10M controls may be wired in parallel with the MASTER control using UTP cable (CAT5, CAT6 or equivalent). The rear-panel MODE switch on each additional remote control is set to SLAVE mode.
Operation is the same for a single control, or for each control connected in a multiple control point installation. The 0 to 10 Vdc ramp voltage is incremented up or down when the front-panel knob is rotated. Acceleration is provided so the rate of change is faster when the knob is rotated more rapidly, yielding a responsive feel and rapid elimination of acoustic feedback. The LED ring display encircling the control knob operates as a virtual pointer. When an -RLC10M is not being adjusted, its display switches to a dim intensity to avoid being a visual distraction. The display returns to a bright intensity during adjustment.
Upon power-up or re-powering after a power loss, the 0 to 10 Vdc ramp will output either a preset level or the last level used. The power-up mode is stored when the control is installed. When programmed for the preset level mode, the user can store a new preset level by holding the MUTE button for more than 3 seconds.
Multiple -RLC10M controls set to the SLAVE MODE may be connected to an RDL RU-VCA2A or RU-VCA6A, utilizing the VCA as the ramp generator. This connection is also possible with OEM equipment accepting open-collector pulses that are compatible with the -RLC10M output pulse rate and width.
|
If you own a RDL switchers & controllers and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M:
Voltage | 0 to 10 VDC (Slave mode input; Master mode output) | Level Control | Optical rotary encoder (minimum to maximum: 5 (slow rotation, no acceleration) 3 (medium rotation, with acceleration) 1 (fast rotation counterclockwise) | Control | Front Panel: 1 x Momentary pushbutton, mute Bottom: 1 x 2-position switch, master slave | Connectors | Back Panel: 7 x Screw terminal block, power and control | Indicators | 1 x LED, Muting 10 x LED, Level | Power Requirement | 24 VDC @ 30 mA, Ground-referenced | Mounting | Mounts in standard US electrical box, RDL WB- or SMB- series boxes | Dimensions (H x W x D) | 4.11 x 1.31 x 0.98" (10.44 x 3.33 x 2.49 cm) | Weight | 0.3 lb (0.1 kg) | Package Weight | 0.5 lb | Box Dimensions (LxWxH) | 4.625 x 3.625 x 2.125" | |
The user manual for the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M can be downloaded in .pdf
format if it did not come with your new switchers & controllers, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other RDL users keep a unique electronic library
for RDL switchers & controllerss,
where you can use our link to download the user manual for the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M.
The user manual lists all of the functions of the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M,
all the basic and advanced features and tells you how to use the switchers & controllers.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from RDL service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M. User manuals are also
available on the RDL website under Pro Audio - Installation Sound - Switchers & Controllers.
Question and answer discussion forum concerning user instructions and resolving problems with the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the RDL D-RLC10M Remote Level Control with Muting, Rotary D-RLC10M
|
|
|
|
|