|
User manual for Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504
- Manufacturer: Telex
- Basic description and contents of package
- Product classification: Pro Audio - Location Sound - Wired Intercoms
- Safety instructions
- Startup and operation of the wired intercoms
- Tips for setting up your Telex
- Settings and expert assistance
- Contact Telex service
- Troubleshooting
- Warranty information
- Price: 717 USD
|
We recommend checking out our discussion threads on the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504,
which address similar problems with connecting and setting up Wired Intercoms Telex.
|
User manual for the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504
The user manual for the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504 provides
necessary instructions for the proper use of the product Pro Audio - Location Sound - Wired Intercoms.
The CM-300L Console Mount User Station w/ an A5F Headset Connector from Telex is a two-channel select console mount user station. The user station is designed to be used in a full duplex, conference line intercom system.
|
If you own a Telex wired intercoms and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504 in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504:
Input Voltage | TW mode: 18-35 V DC LP option: 15-35 V DC Battery: 12-35 V DC (reduced performance) | Current | Quiescent 23 milliamperes ±10% 33 milliamperes ±10% Operating 25 Ω headphones 37 milliamperes ±10% 45 milliamperes ±10% Operating 25 Ω headphones + call light 60 milliamperes ±10% Impedance across line: 10,000 Ω, minimum | Environmental Conditions | Temperature Operating: 32-140°F (0-60°C) Storage: -40-185°F (-40-85°C) Humidity Operating and storage: 5-95% non-condensing | Noise | One unit: -75 dBu Ten units: -67 dBu | Panel Microphone Preamp | Microphone preamplifier Input impedance: 470 Ω/dynamic mic Source impedance: 200 Ω, nominal Maximum input level: 150 millivolts Frequency response: 100Hz-10kHz ±3 dB (-54 dBu input) Limiter range: 30 dB Carbon mic excitation current: 10 millliamperes, nominal | Source | Current source Transfer ratio: 3.3 milliamperes/volt=3.3 millisiemens Output: ±5 milliamperes into 200 Ω = ±1 volt peak, nominal | Headphone Amp | Voltage gain: 34 dB Output voltage: 8 volts peak-to-peak into 25 ½ Output power: ½ watt peak into 25 Ω Frequency response: 150Hz-8kHz ±3dB Headphone impedance range: 25-600 Ω (600-2000 with reduced levels) Note: Do not use headphones with impedance less than 25 Ω. Sidetone adjustment range: -20dB to full on | Call Light Levels | Signaling frequency: 20,000Hz ±100Hz Flashing rate: 5Hz ±2Hz | Connectors | Headset connector Dynamic microphone: XLR type 4-pin female Carbon microphone: ¼" standard phone jack, 3-circuit Live connection: Input: XLR type 3-pin female Loop/external: XLR type 3-pin female | Finish | Front panel: light gray enamel paint, Federal standard 595A Color #26492Chassis: gold iridite over aluminum | Dimensions (H x W x D) | 2.8 x 6.3 x 6.4" (69.9 x 158.75 x 162.6mm) | Weight | 1.2 lb. (0.6kg) | |
The user manual for the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504 can be downloaded in .pdf
format if it did not come with your new wired intercoms, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Telex users keep a unique electronic library
for Telex wired intercomss,
where you can use our link to download the user manual for the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504.
The user manual lists all of the functions of the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504,
all the basic and advanced features and tells you how to use the wired intercoms.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Telex service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504. User manuals are also
available on the Telex website under Pro Audio - Location Sound - Wired Intercoms.
Question and answer discussion forum concerning user instructions and resolving problems with the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504 - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Telex CM-300L Console Mount User Station w/ an A5F F.01U.118.504
|
|
|
|
|