User manual Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A
Operating instructions and pdf manual for use - Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A User manual, User manual Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A, Aiphone, NE-NVP-2DC/A, Sub, Station, with, S
User manual for Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A
Manufacturer: Aiphone
Basic description and contents of package
Product classification: Surveillance - Intercoms - Door Stations
Safety instructions
Startup and operation of the door stations
Tips for setting up your Aiphone
Settings and expert assistance
Contact Aiphone service
Troubleshooting
Warranty information
We recommend checking out our discussion threads on the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A,
which address similar problems with connecting and setting up Door Stations Aiphone.
User manual for the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A
The user manual for the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A provides
necessary instructions for the proper use of the product Surveillance - Intercoms - Door Stations.
The Aiphone NE-NVP-2DC/A Sub Station with Standard Call Button and Red Emergency Call Button is a vandal-proof sub station with DPDT contacts, designed for use with the NDR or NDRM Intercom System. It is constructed of 11-gauge carbon steel with a white powder-coated finish. The NE-NVP-2DC/A Sub Station can be flush or surface mounted into a 3-gang masonry type box (sold separately) and includes tamper-proof screws and a wrench for installation.
If you own a Aiphone door stations and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A:
Specifications
Power Source
Supplied by master station
Speaker
20 ohms, 2-½" diameter, water proof and puncture resistant
Button
Call Button: SPST, normally open push button. Red button: Activates DPDT N/O contacts (Brn/Red, Org/Yel pairs). DPDT Relay Contacts: 6 A @ 125 VAC or 6 A @ 30 VDC. Minimum 25,000 operations
Call Alerts
Standard call button at sub latches call at NEM master until answered. Red emergency button is "push-on, push-off", which activates or deactivates DPDT contacts and red LED. "Push-on" activates relay and LED, "push-off" deactivates them.
Communication
Hands free at sub. Master is push-to-talk or VOX with handset
Terminals
Red: To Station Black: To "E" (Common) White: To "H" (12 VDC - Powers DPDT contacts and LED) Green: For use with LEW-5NE Blue: For use with a local corridor lamp
Wiring
Communication and Standard Call: 3 conductors homerun; or 2 common plus 1 individual per sub, looped through each sub. Shielded cable recommended. Use Aiphone #822203 or #821803 wires for homerun wiring, #822206 for up to 4 stations. DPDT contacts require 4 additional wires from each sub station.
Wiring Distance
420' (128 m) with 22 AWG; 1,000' (305 m) with 18 AWG (standard call and communication).
Finish
11-gauge carbon steel with powder-coated white baked epoxy finish
Dimensions (H x W x D)
7.5 x 5.5 x 2.0" (19 x 14 x 5.1 cm)
Weight
2.4 oz (68 g) ceramic magnet
The user manual for the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A can be downloaded in .pdf
format if it did not come with your new door stations, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Aiphone users keep a unique electronic library
for Aiphone door stationss,
where you can use our link to download the user manual for the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A.
The user manual lists all of the functions of the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A,
all the basic and advanced features and tells you how to use the door stations.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Aiphone service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A. User manuals are also
available on the Aiphone website under Surveillance - Intercoms - Door Stations.
Question and answer discussion forum concerning user instructions and resolving problems with the Aiphone NE-NVP-2DC/A Sub Station with Standard Call NE-NVP-2DC/A - no comments have been made yet - be the first to add a comment
Why is the blue light (wireless symbol)...what is it on...its a blue light. I have had these for years and have never had that light come on and it is not allowing me to print! What do I do to turn it off? ...K&M manual - K&M 200 Telescoping Microphone Stand (Black) 20000-500-55 Posted by: jpdaval69 2024-09-10 00:50:11
I need the service manual/schematic of Universal Audio Solo/610 Serial number: 2310 MfgDt: 0607.
I hope you have it and I'm willing to be charged for it.
Best Regards....