User manual for American Dynamics SensorNet to RS-422 Code Converter RCSN422
- Manufacturer: American Dynamics
- Basic description and contents of package
- Product classification: Surveillance - Surveillance Video - Video Transmission - Data Transmission
- Safety instructions
- Startup and operation of the data transmission
- Tips for setting up your American Dynamics
- Settings and expert assistance
- Contact American Dynamics service
- Troubleshooting
- Warranty information
- Price: 367 USD
|
We recommend checking out our discussion threads on the American Dynamics SensorNet to RS-422 Code Converter RCSN422,
which address similar problems with connecting and setting up Data Transmission American Dynamics.
|
User manual for the American Dynamics SensorNet to RS-422 Code Converter RCSN422
The user manual for the American Dynamics SensorNet to RS-422 Code Converter RCSN422 provides
necessary instructions for the proper use of the product Surveillance - Surveillance Video - Video Transmission - Data Transmission.
The American Dynamics SensorNet to RS-422 Code Converter converts SensorNet communication from the ADTT16E controller to the RS-422 protocol. This provides a migration path from VM1 to ADTT16E. The universal mount design allows the Class 2 LPS certified unit to be mounted on a wall, surface, or rack. One SensorNet port accommodates the ADTT16E controller, and 7 RS-422 output ports accommodate domes and J-Boxes.
|
If you own a American Dynamics data transmission and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the American Dynamics SensorNet to RS-422 Code Converter RCSN422 in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the American Dynamics SensorNet to RS-422 Code Converter RCSN422:
Operational | SensorNet Interface: Two decimal rotary switches with knobs for selecting address. Switch selectable terminating resistor.
Network Distance: 1 km (3,000 ft) Maximum Loads: 32/node Topologies: Daisy chain backbone, star Resistor: Slide switch selectable Transmission Medium: Single unshielded twisted pair (UTP) 22 AWG, non-polarized
SensorNet Connector: Pluggable, Euro-style screw terminal, 2 pin
Surge Protection: Isolation transformer coupled, 2000 Vrms / PTC resettable fuse protects transformer / Gas discharge tube impulse rated at 10KA / TVS rated at 5.6 V, 40 A, 0.1 joules, 8/20 ms impulse
SensorNet 422 Serial Communication Interface Seven line driver and receiver serial communications ports.
Network Distance: 1 km (3,000 ft) Maximum Loads: 1/node or 10/node - daisy chained (SpeedDome version 6.1 and later, SpeedDome Ultra/Optima series)
Transmission Medium: 2 shielded twisted pair (STP) 22 AWG, polarized
RS-422 Connector: Euro-style screw terminal,5 pin plug
Surge Protection: TVS rated at 5.6 V, 40 A, 0.1 joules, 8/20 ms impulse
Diagnostics Communication Ping test
RS-422: Loop-back test, reset button Front Panel LEDs: Primary power, microprocessor, SensorNet activity, RS-422 activity, SensorNet noise | Electrical | Power Input: 100-128VAC Power Consumption: 20 watts maximum Voltage to Converter: 20 to 26 VAC, Class 2 LPS Cable to Transformer: 5 meter, 18 AWG, 24 VAC | Mounting | Universal mount: wall, surface, rack (19-inch EIA) | Operating Temperature | 32 - 122°F (0 - 50°C) | Dimensions (HxWxD) | Desktop: 1.72 x 17.25 x 5.14" (43.7 x 438.2 x 130.6mm) Rack Mounted: 1.72 x 18.96 x 5.13" (43.7 x 481.6 x 130.6mm) | Weight | 3.3 lbs (1.5kg) | Package Weight | 11.35 lb | Box Dimensions (LxWxH) | 22.6 x 22.1 x 8.9" | |
The user manual for the American Dynamics SensorNet to RS-422 Code Converter RCSN422 can be downloaded in .pdf
format if it did not come with your new data transmission, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other American Dynamics users keep a unique electronic library
for American Dynamics data transmissions,
where you can use our link to download the user manual for the American Dynamics SensorNet to RS-422 Code Converter RCSN422.
The user manual lists all of the functions of the American Dynamics SensorNet to RS-422 Code Converter RCSN422,
all the basic and advanced features and tells you how to use the data transmission.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from American Dynamics service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the American Dynamics SensorNet to RS-422 Code Converter RCSN422. User manuals are also
available on the American Dynamics website under Surveillance - Surveillance Video - Video Transmission - Data Transmission.
Question and answer discussion forum concerning user instructions and resolving problems with the American Dynamics SensorNet to RS-422 Code Converter RCSN422 - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the American Dynamics SensorNet to RS-422 Code Converter RCSN422
|
|
|
|
|