User manual Ashly nXp3.04 Network Power Amplifier NXP3.04
Operating instructions and pdf manual for use - Ashly nXp3.04 Network Power Amplifier NXP3.04 User manual, User manual Ashly nXp3.04 Network Power Amplifier NXP3.04, Ashly, nXp3.04, Network, Power, Amplifier, NXP3.04, Video
User manual for Ashly nXp3.04 Network Power Amplifier NXP3.04
Manufacturer: Ashly
Basic description and contents of package
Product classification: Pro Audio - Installation Sound - 70-Volt Amplifiers
Safety instructions
Startup and operation of the 70-volt amplifiers
Tips for setting up your Ashly
Settings and expert assistance
Contact Ashly service
Troubleshooting
Warranty information
We recommend checking out our discussion threads on the Ashly nXp3.04 Network Power Amplifier NXP3.04,
which address similar problems with connecting and setting up 70-Volt Amplifiers Ashly.
User manual for the Ashly nXp3.04 Network Power Amplifier NXP3.04
The user manual for the Ashly nXp3.04 Network Power Amplifier NXP3.04 provides
necessary instructions for the proper use of the product Pro Audio - Installation Sound - 70-Volt Amplifiers.
The nXp3.04 Network Power Amplifier from Ashly Audio is the networkable version of the nX amplifier. It comes with Ethernet control, serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability. All these are controlled using Ashly Audio's Protea software suite. This amplifier is designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces, and convention centers.
If you own a Ashly 70-volt amplifiers and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Ashly nXp3.04 Network Power Amplifier NXP3.04 in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Ashly nXp3.04 Network Power Amplifier NXP3.04:
At 50 Hz Nominal (Automatic Sensing SMPS): 120 VAC Operating Range: 70 to 135 VAC Minimum Power-Up: 85 VAC
At 60 Hz Nominal (Automatic Sensing SMPS): 240 VAC Operating Range: 140 to 270 VAC Minimum Power-Up: 170 VAC
Connector
Power Cable Connector: 32 A powerCON
Output
For Max Output Power Per Channel, EIAJ Test Standard, 1 kHz, 20 Hz to 20 kHz, 1% THD & Low Z Output: 2 Ω: 3,000 W 4 Ω: 2,000 W 8 Ω: 1,250 W
For Low Z output, Bridge Mode, 20 Hz to 20 kHz & 1% THD: 4 Ω: 6,000 W
For Output Per Channel: 70 V: 2,450 W 100 V: 1,250 W Note: All Channels Driven
Power Draw
Sleep Mode: < 1 W Standby Mode: 70 W Idle (No Signal): 100 W Note: All Channels Driven
Current Draw
For 120 VAC Sleep Mode: 0.1 A Standby Mode: 1.30 A Idle (No Signal): 1.85 A
For 240 VAC Sleep Mode: 0.05 A Standby Mode: 0.65 A Idle (No Signal): 0.92 A Maximum for all Channels Driven: For 120 VAC Typical: 29.5 A For 240 VAC Typical: 14.7 A
Dissipation
Thermal Dissipation: Sleep Mode: <3.4 BTU/hr Standby Mode: 238 BTU/hr Idle (no signal): 340 BTU/hr Typical (1 / 8 Max Power): 2,720 BTU/hr Note: All Channels Driven
LED Indicators
Front Panel LED Indicators: White LED: Power Switch: On, off, standby (flashing)
Red LED: Clip / Mute Per Channel: Clip @ 1 dB below full output / mute Protect: On, Off
Green LED: Signal Per Channel: -18 dBu Bridge Per Channel Pair: On, off Com: On, for Ethernet data or device ID Current Per Channel: Proportional to output
Yellow LED: Temperature Per Channel: On dim at 90% max operating temperature, full bright + protect at 100% Sleep: On, amplifier is asleep from audio inactivity Disable: On, power switch & front panel attenuators are disabled
Protēa DSP Options: Analog, auto (net, AES3, analog) Note: All DSP functions can be linked to 1 of 16 link groups
Limiter
Brick Wall Limiter: Threshold: -20 to 20 dBu Ratio: Infinite Attack: 0.2 to 50 ms/dB Release: 5 to 1000 ms/dB
Control
Advanced Gate Controls: Key Engage Enable: Yes Key Frequency: 20 Hz to 20 kHz Key Bandwidth: 0.016 to 3.995 octave
Gain
Gain (with / without VCA): -50 to 12 dB, off, polarity invert Digital VCA Groups: 4 available Remote RD8C Gain: Enable per channel, 0 dB to -∞ WR-5 (neWR-5) Remote Gain: 0 to -50 dB, mute
EQ Type
For 31-Band Filter Type: Constant Q or proportional Bandwidth: 0.499 octave to 0.25 octave
For Parametric 2,4,6, or 10 Band Frequency: 20 to 20 kHz Level: -30 to 15 dB Q Value: 0.016 to 3.995 octave For Hi / Low Shelf 6 / 12 dB/octave Frequency: 20 Hz to 20 kHz Level: -15 to 15 dB
For All Pass Frequency: 20 Hz to 20 kHz
For Variable Q HP / LP Frequency: 20 Hz to 20 kHz Q Value: 3.047 to 0.267
For Notch / Bandpass Frequency: 20 Hz to 20 kHz Q Value: 92.436 to 0.267
Sampling Rate: At 48kHz (Input Time, Distance & Temperature) Speaker Delay: 0 to 21 ms Delay: 0 to 682 ms At 96 kHz (Input Time, Distance & Temperature) Speaker Delay: 0 to 10.6 ms Delay: 0 to 341 ms
Audio Metering
Range: -60 to 20 dBu Increments: 1 dB Peak Hold Indicator: Yes
Signal Generator
Pink Noise, White Noise, Sine Wave Signal Level: Off, -50 to 20 dBu Sine Wave Frequency: 20 Hz to12 kHz
Processor
Input A/D, Output D/A: 24 bit DSP Processors: 32-bit floating point Sample Rates: 48 kHz, 96 kHz Propagation Delay @ 48 kHz: 1.42 ms Propagation Delay @ 96 kHz: 0.71 ms
Mixer
Gain (0.5 dB Increments): Off, -50 to 12dB Mute: Per channel Auto-mixer Enabled: Per channel Global Auto-mixer Response: 0.01 to 2 sec Enable Ducking at Mixer: Yes Ducking LED: Per channel if enabled Metering: Level, auto-mixer level
Filters
Number: 12 In/Out per filter: Yes Lock per filter and global lock: Yes Filter Modes: Float, Restricted, Manual Filter Type: Notch, Parametric Filter Frequency Range: 20 Hz to 20 kHz Notch Filter: -∞ Parametric Filter: 15 dB to -30 dB Filter Bandwidth: 0.016 to 3.995 octave Detector Sensitivity: 5 levels Float Time: 5 minutes to 24 hours
The user manual for the Ashly nXp3.04 Network Power Amplifier NXP3.04 can be downloaded in .pdf
format if it did not come with your new 70-volt amplifiers, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Ashly users keep a unique electronic library
for Ashly 70-volt amplifierss,
where you can use our link to download the user manual for the Ashly nXp3.04 Network Power Amplifier NXP3.04.
The user manual lists all of the functions of the Ashly nXp3.04 Network Power Amplifier NXP3.04,
all the basic and advanced features and tells you how to use the 70-volt amplifiers.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Ashly service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Ashly nXp3.04 Network Power Amplifier NXP3.04. User manuals are also
available on the Ashly website under Pro Audio - Installation Sound - 70-Volt Amplifiers.
Question and answer discussion forum concerning user instructions and resolving problems with the Ashly nXp3.04 Network Power Amplifier NXP3.04 - no comments have been made yet - be the first to add a comment
Why is the blue light (wireless symbol)...what is it on...its a blue light. I have had these for years and have never had that light come on and it is not allowing me to print! What do I do to turn it off? ...K&M manual - K&M 200 Telescoping Microphone Stand (Black) 20000-500-55 Posted by: jpdaval69 2024-09-10 00:50:11
I need the service manual/schematic of Universal Audio Solo/610 Serial number: 2310 MfgDt: 0607.
I hope you have it and I'm willing to be charged for it.
Best Regards....True Dock not recognizing hard drives - Kingwin True Dock Super-Speed USB 3.0 to TD-2535U3 Posted by: bf1955 2024-08-22 15:34:26
True Dock is not recognizing HDD, the HDD light does not come on, even though the power light does come one....