PDF-MANUALS.com | User manual here!
User manual

User manual Axis Communications A1001 Network Door Controllers 0540-021

Operating instructions and pdf manual for use - Axis Communications A1001 Network Door Controllers 0540-021 User manual, User manual Axis Communications A1001 Network Door Controllers 0540-021, Axis, Communications, A1001, Network, Door, Controller


User manual for Axis Communications A1001 Network Door Controllers 0540-021

Axis Communications A1001 Network Door Controllers 0540-021
  • Manufacturer: Axis Communications
  • Basic description and contents of package
  • Product classification: Surveillance - Access Control - Access Controllers
  • Safety instructions
  • Startup and operation of the access controllers
  • Tips for setting up your Axis Communications
  • Settings and expert assistance
  • Contact Axis Communications service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the Axis Communications A1001 Network Door Controllers 0540-021, which address similar problems with connecting and setting up Access Controllers Axis Communications.



User manual for the Axis Communications A1001 Network Door Controllers 0540-021

The user manual for the Axis Communications A1001 Network Door Controllers 0540-021 provides necessary instructions for the proper use of the product Surveillance - Access Control - Access Controllers.

The pack of Axis Communications A1001 Network Door Controllers includes 10 door controllers. This network door controller offers an open, non-proprietary platform for access management that meets the requirements of advanced enterprise systems as well as smaller installations. It comes with built-in software for basic access management. In addition, it is compatible with third-party software, allowing integration with solutions provided by Axis partners.
If you own a Axis Communications access controllers and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Axis Communications A1001 Network Door Controllers 0540-021 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Axis Communications A1001 Network Door Controllers 0540-021:
Controller
Reader Interface Up to 2 readers per controller [Wiegand, RS485 (OSDP)] with supported card formats
Doors 1 to 2 doors per controller

Power consumption dependent, maximum load for readers and other equipment is 7.5 W with PoE and 14 W with 10 to 30 VDC

Access Credentials up to 15,000 with third-party access management software depending on server capacity
Event History: 30,000 first in, first out (FIFO) per controller
Schedule Access: Unlimited or third-party software dependent
I/O
Input & Output Reader I/O:
DC Output: 2 x 12 VDC output max 300 mA; 2x 4 configurable inputs/outputs
Digital Input: 0 to 40 VDC maximum
Digital Output: 0 to 40 VDC maximum, open drain, maximum 100 mA
Reader Data: RS-485 full duplex, RS-485 half duplex, Wiegand
Auxiliary I/O:
1 x 3.3 VDC output, maximum 100 mA
2x configurable inputs/output
Digital Input: 0 to 40 VDC maximum
Digital Output: 0 to 40 VDC maximum, open drain, maximum 100 mA
Connectors Door: 2 x 2 input for door monitors and REX
Digital Input: 0 to 40 VDC maximum
Functionality I/O: Pre-configured for readers and door monitors, input trigger, output toggle/pulse
Network
Security Password protection, IP address filtering, HTTPS encryption, IEEE 802.1x network access control, digest authentication, user access log

Includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit

Supported Protocols IPv4, HTTP, HTTPS, SSL/TLS, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS

Includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit

System Integration
Application Programming Interface Open API for software integration, including VAPIX and AXIS Camera Application Platform
AXIS Video Hosting System (AVHS) with One-Click Camera Connection
ONVIF Profile C conformant
Triggers & Events
Tamper Detection Removal of unit cover/tamper front
Removal of unit from wall/tamper back, reader tamper
Event Log Configurable by time and topic, alarm acknowledgement
Event Action Notification via email, HTTP and TCP, external output port, status LED
Event Trigger Tamper detection, power loss, network loss, configuration, door, event logger, hardware, input signal, schedule, system, time
General
Material Plastic casing
Software Configuration and basic access control management through Internet Explorer, Firefox, Chrome, or Safari
Memory 256 MB RAM, 4 Gb flash
Power Power In: 10 to 30 VDC, maximum 26 W or Power over Ethernet IEEE 802.3af/at type 1 class 3
Power Out & Relay: 1 x 12 VDC, maximum 500 mA
1 x Solid State Relay: 30 VDC, maximum 700 mA
Power Out Lock: 2 x 12 VDC, maximum 500 mA

Power consumption dependent, maximum load for readers and other equipment is 7.5 W with PoE and 14 W with 10 to 30 VDC

Connectors RJ45 10BaseT/100BaseTX Terminal Blocks: DC power, 10 inputs/outputs, RS-485/Wiegand, relay
Cable Size for Connectors:
CSA: AWG 28 to 16
CUL/UL: AWG 30 to 14
Approvals EN 55022 class B, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-1, EN 61000-6-2, FCC part 15 sSubpart B class B, ICES-003 class B, C-tick AS/NZS CISPR22 class B, VCCI class B, IEC/EN/UL 60950-1, UL 294, UL 2043, EN 50581
Operating Conditions Temperature: 32 to 122°F (0 to 50°C)
Humidity: 20 to 85% relative humidity (non-condensing)
Dimensions 1.8 x 7.1 x 7.1" (4.6 x 18.0 x 18.0 cm)
Weight 1.1 lb (0.5 kg)
The user manual for the Axis Communications A1001 Network Door Controllers 0540-021 can be downloaded in .pdf format if it did not come with your new access controllers, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Axis Communications users keep a unique electronic library for Axis Communications access controllerss, where you can use our link to download the user manual for the Axis Communications A1001 Network Door Controllers 0540-021.

The user manual lists all of the functions of the Axis Communications A1001 Network Door Controllers 0540-021, all the basic and advanced features and tells you how to use the access controllers. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Axis Communications service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Axis Communications A1001 Network Door Controllers 0540-021. User manuals are also available on the Axis Communications website under Surveillance - Access Control - Access Controllers.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Axis Communications A1001 Network Door Controllers 0540-021 - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the Axis Communications A1001 Network Door Controllers 0540-021

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

Redfield 3-9X40 Accu Range - Redfield 3-9x40 Revolution Riflescope (Accu-Range) 67095
Posted by: CHARLES MIKULA
2024-04-26 00:49:10

I lost my Redfield owners manual in a recent move from Virginia to Florida! Can I receive a replacement?...
Input Power - Gemini XGA-3000 Professional Power Amplifier XGA-3000
Posted by: Brent
2024-04-25 22:33:49

What is the input power requirements? Or better yet, what is the size fuse (in amps) that is listed as a 5mmx20mm?...
User Manual - Odyssey Innovative Designs FZ1316WDLXII Flight FZ1316WDLX-II
Posted by: Mike McGrath
2024-04-25 18:51:37

Please send me the user manual for Odyssey FR1316WDLX. Thanks!...
MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
Posted by: Jae Gil, Ha
2024-04-25 09:48:07

needs manual file...
Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
Posted by: Judy Whiteley
2024-04-24 16:51:27

Please send user’s manual in normal size print...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx