|
User manual for Grace Design m905 Reference Monitor Controller A905
- Manufacturer: Grace Design
- Basic description and contents of package
- Product classification: Pro Audio - Recording - Studio Monitor Controllers
- Safety instructions
- Startup and operation of the studio monitor controllers
- Tips for setting up your Grace Design
- Settings and expert assistance
- Contact Grace Design service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the Grace Design m905 Reference Monitor Controller A905,
which address similar problems with connecting and setting up Studio Monitor Controllers Grace Design.
|
User manual for the Grace Design m905 Reference Monitor Controller A905
The user manual for the Grace Design m905 Reference Monitor Controller A905 provides
necessary instructions for the proper use of the product Pro Audio - Recording - Studio Monitor Controllers.
The Grace Design m905 is a reference monitor controller and high-quality digital-to-analog converter, designed to deliver mastering-quality monitoring to your home or professional studio.
Featuring balanced and unbalanced analog inputs, and AES, S/PDIF and ADAT digital inputs, the m905 allows you to switch between a variety of input sources. Additionally, the unit has three stereo pairs of balanced speaker outputs with two assignable mono sub outputs, giving you a versatile selection of monitoring options when mixing or mastering.
|
If you own a Grace Design studio monitor controllers and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Grace Design m905 Reference Monitor Controller A905 in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Grace Design m905 Reference Monitor Controller A905:
THD + N | At Maximum Volume, 1 kHz, 22 Hz to 22 kHz BW +20 dBu Out: <0.0008% +10 dBu Out: <0.0008% 0 dBu Out: <0.002% | Distortion | Inter-Modulation Distortion SMPTE / DIN 4:1 50 Hz, 7 kHz At +20 dBu Out: <0.002% At 0 dBu Out: <0.0015% | Frequency Response | Balanced Inputs +/-3 dB: 3 Hz to 1.25 MHz Unbalanced Input +/-3 dB: 3 Hz to 275 kHz | Dynamic Range | 20 to 22 kHz Bandwidth: 118 dB 20 to 22 kHz Bandwidth and A-Weighting Filter: 121 dB | Output Noise | 20 to 22 kHz Bandwidth, at -20 dB Gain: -99 dBu 20 to 22 kHz Bandwidth and A-Weighting Filter, at -20 dB Gain: -102 dBu | Deviation | Phase Deviation: 20 Hz to 20 kHz: <10° 10 Hz to 100 kHz: <19° | Cross Talk | Crosstalk Any Channel: 100 Hz: <104 dB 1 kHz: <100 dB 20 kHz: <79 dB | Balanced Input | For Balanced Input: 60 Hz: >90 dB 1 kHz: >85 dB 10 kHz: >70 dB | Gain Range | -104 dB to +13 dB | Channel | Channel Tracking Accuracy: +/-0.1 dB | Maximum Output Level | +26 dBu | Maximum Input Level | Balanced Inputs: +29 dBu Unbalanced Inputs: +21 dBu | Impedance | Balanced Inputs: 88 kΩ Unbalanced Inputs: 53 kΩ Balanced Outputs: 300 Ω Minimum Load Impedance: 300 Ω | Mic Pre Gain | External Talkback Mic Preamp Gain: +7 dB to +70 dB in 1 dB steps | Output Level | User Selectable (0 dBFS): -76 dBu to +24 dBu in 0.5 dB steps Fixed output trim range: (0.5 dB steps) | THD + N | 1 kHz, -1 dBFS, (0 dBFS = +20 dBu), 20 to 22 kHz Bandwidth: 0.0006% | Dynamic Range | 20 to 22 kHz Bandwidth, 0 dBFS = +20 dBu (AES 17 filter): 117 dB 20 to 22 kHz Bandwidth, 0 dBFS = +20 dBu (A-weighted): 119 dB | Lock Range | AES3 / SPDIF: 44.1 kHz +/-400 Hz 48 kHz +/-700 Hz 88.2 kHz +/-1200 Hz 96 kHz +/-1300 Hz 176.4 kHz +/-2000 Hz 192 kHz +/-2000 Hz TOSLINK: 44.1 kHz +/-400 Hz 48 kHz +/-700 Hz 88.2 kHz +/-1200 Hz 96 kHz +/-1300 Hz ADAT: 8 Channels at 44.1 kHz and 48 kHz 4 Channels at 88.2 kHz and 96 kHz (s/mux) 44.1 kHz +/-50 Hz 48 kHz +/-70 Hz 88.2 kHz +/-50 Hz 96 kHz +/-70 Hz USB: 44.1kHz 48 kHz 88.2 kHz 96 kHz 176.4 kHz 192 kHz DSD64 2.8224 MHz DSD128 5.6448 MHz | Capture Bandwidth | s-Lock Capture Range 44.1 kHz: +/- 6 Hz 48 kHz: +/- 7 Hz 88.2 kHz: +/- 14 Hz 96 kHz: +/- 20 Hz 176.4 kHz: +/- 24 Hz 192 kHz: +/- 30 Hz | Word Clock | Impedance (switchable): 75 ohm / 1 Mohm Minimum Voltage: 3V peak to peak Maximum Voltage: 5V peak to peak Word Clock Frequencies Supported: 44.1, 48, 88.2, 96, 176.4, 192 kHz Superclock Frequencies Supported: N/A | Power Consumption | 60 W | Input Voltage | 100 to 240 VAC 50-60 Hz | Dimensions | Main Chassis IEC 2U: 3.50 x 10.50 x 17.00" (8.89 x 26.67 x 43.18 cm) Remote Control Unit: 8.90 x 5.10 x 2.20" (22.61 x 12.95 x 5.59 cm) | Weight | Main Chassis: 7.80 lb (3.54 kg) Remote Control Unit: 2.20 lb (1.00 kg) | Package Weight | 20.15 lb | Box Dimensions (LxWxH) | 26.0 x 18.0 x 11.0" | |
The user manual for the Grace Design m905 Reference Monitor Controller A905 can be downloaded in .pdf
format if it did not come with your new studio monitor controllers, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Grace Design users keep a unique electronic library
for Grace Design studio monitor controllerss,
where you can use our link to download the user manual for the Grace Design m905 Reference Monitor Controller A905.
The user manual lists all of the functions of the Grace Design m905 Reference Monitor Controller A905,
all the basic and advanced features and tells you how to use the studio monitor controllers.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Grace Design service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Grace Design m905 Reference Monitor Controller A905. User manuals are also
available on the Grace Design website under Pro Audio - Recording - Studio Monitor Controllers.
Question and answer discussion forum concerning user instructions and resolving problems with the Grace Design m905 Reference Monitor Controller A905 - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Grace Design m905 Reference Monitor Controller A905
|
|
|
|
|