PDF-MANUALS.com | User manual here!
User manual

User manual Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49

Operating instructions and pdf manual for use - Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49 User manual, User manual Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49, Neumann, TLM, 49, Cardioid, Studio, Condenser, Microphon


User manual for Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49

Overall rating 5.0
Overall Rating: 5.0

100% of respondents would recommend this to a friend.
Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49
  • Manufacturer: Neumann
  • Basic description and contents of package
  • Product classification: Pro Audio - Recording - Large Diaphragm Condenser
  • Safety instructions
  • Startup and operation of the large diaphragm condenser
  • Tips for setting up your Neumann
  • Settings and expert assistance
  • Contact Neumann service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49, which address similar problems with connecting and setting up Large Diaphragm Condenser Neumann.



User manual for the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49

The user manual for the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49 provides necessary instructions for the proper use of the product Pro Audio - Recording - Large Diaphragm Condenser.

The TLM 49 Cardioid Studio Condenser Microphone from Neumann is a large-diaphragm studio microphone with a cardioid directional characteristic and a warm sound, optimized for vocal performance. It is supplied as a set, with an elastic suspension. The design is inspired by the Neumann M 49 and M 50 microphones of the 1950s. The "sound design" is also oriented toward that of the M 49 and the U 47. This microphone ensures low self-noise and the use of high gain levels.

The large-diaphragm capsule of the TLM 49 provides a cardioid directional characteristic with a tendency toward supercardioid, due to the capsule construction. Following the example of the M 49, high frequencies are more directional. The capsule diameter is 34mm. The capsule is oriented so that the microphone is addressed from the front.

The TLM 49 uses the K 47 capsule, which was also used in the M 49 and the U 47. The capsule has a linear frequency response up to the upper mid-range. Above 2 kHz there is a gentle presence boost up to 3 dB. The capsule is enclosed by a large microphone head grille, which is acoustically very open and is neutral with regard to the sound.

With TLM technology the usual output transformer is replaced by an electronic circuit. As with traditional transformers, it ensures good common mode rejection, and prevents RF interference that may influence the balanced audio signal. Noise signals which affect the balanced modulation line are effectively suppressed. The microphone can operate at sound pressure levels of up to 129 dB without distortion, and provides a dynamic range of 117 dB (A-weighted).

The entire interior structure is mounted elastically, to prevent the transmission of structure-borne noise. In addition, the capsule is mounted with a rubber shock mount. Due to the wide frequency response, the TLM 49 can also transmit low-frequency signals without coloration. The TLM 49 is supplied with the elastic suspension EA 3, which effectively protects the microphone from structure-borne noise.
If you own a Neumann large diaphragm condenser and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49:

Go To

Operating Principle Pressure Gradient
Transducer Condenser
Polar Pattern Cardioid
Frequency Range 20 Hz to 20 kHz
Signal to Noise Ratio 71 dB CCIR
82 dB A-Weighted
Equivalent Noise Level 23 dB CCIR
12 dB A-Weighted
Maximum SPL 110 dB SPL < 0.5%
129 dB SPL < 5%
Impedance 50 ohms
Load Impedance 1 kOhms
Sensitivity 13 mV/PA @ 1 kHz into 1 kOhms
Power Requirements 48 V+/- 4 V
Output Connectors 3-Pin XLR
Operating Current Consumption 3.2µA
General
Length 6.50 " (165 mm )
Diameter 3.07 " (78 mm)
Weight 1.82 lb (825 g)
Packaging Info
Package Weight 3.6 lb
Box Dimensions (LxWxH) 7.7 x 6.6 x 5.1"
The user manual for the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49 can be downloaded in .pdf format if it did not come with your new large diaphragm condenser, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Neumann users keep a unique electronic library for Neumann large diaphragm condensers, where you can use our link to download the user manual for the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49.

The user manual lists all of the functions of the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49, all the basic and advanced features and tells you how to use the large diaphragm condenser. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Neumann service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49. User manuals are also available on the Neumann website under Pro Audio - Recording - Large Diaphragm Condenser.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49 - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the Neumann TLM 49 Cardioid Studio Condenser Microphone TLM 49

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

MDV-1BA manual - METRO DataVac DataVac Pro & Micro Cleaning Tools MDV-1BA
Posted by: Jae Gil, Ha
2024-04-25 09:48:07

needs manual file...
Sony Audio System CMT-SBT 100 - Sony CMT-SBT100 Micro Music System with Bluetooth CMTSBT100
Posted by: Judy Whiteley
2024-04-24 16:51:27

Please send user’s manual in normal size print...
Need manual - Sunpak Universal SelfieWand for Smartphones, Point SP-BSW-BK
Posted by: Sam
2024-04-23 19:26:40

Please send...
Yongnuo YN467 Manual - Yongnuo YN-460II Flash Speedlite YN-460II
Posted by: Robert
2024-04-21 16:35:48

Please may I have a PDF copy of the manual? Thank you....
hk EA600 amp - HK AUDIO EA600 600W Class-D Power Amplifier EA600
Posted by: Ky Trinh
2024-04-20 09:31:19

Can you directly connect the ea600 amp to the E110A active subwoofer?...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx