User manual Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100
Operating instructions and pdf manual for use - Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100 User manual, User manual Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100, Optex, REDWALL-V, Series, SIP-100, Outdoor, Wi
User manual for Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100
Manufacturer: Optex
Basic description and contents of package
Product classification: Surveillance - Alarm Systems - Motion Detectors
Safety instructions
Startup and operation of the motion detectors
Tips for setting up your Optex
Settings and expert assistance
Contact Optex service
Troubleshooting
Warranty information
Price: 815 USD
We recommend checking out our discussion threads on the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100,
which address similar problems with connecting and setting up Motion Detectors Optex.
User manual for the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100
The user manual for the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100 provides
necessary instructions for the proper use of the product Surveillance - Alarm Systems - Motion Detectors.
The REDWALL-V Series SIP-100 Outdoor Wired Synthesized Intelligent PIR with Creep Zone from Optex offers long range detection of 300' for triggering CCTV systems in large areas outside. It has an intelligent detection system that uses data from the ambient environment, such as temperature and illuminance conditions, to automatically adjust the sensitivity. In addition,the SIP-100 offers a total of 3 outputs: 2 separate outputs for far and near areas and another for creep-zone detection. Multiple outputs are useful for activating video transmission systems and controlling PTZ cameras. The detection angle in the main area of the SIP-100 can be adjusted to easily match a camera's field of view and the unit is also equipped with anti-rotation and anti-masking functions, which can detect vandalism or tampering with the unit.
If you own a Optex motion detectors and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100 in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100:
Specifications
Detection Method
Passive infrared
Installation
Commercial, government, industrial
Coverage
Main: 330 x 10' (100 x 3 m) Creep Zone: 10 x 16'(3 x 5 m) installed at 7.6' (2.3 m) height, 20 x 30' (6 x 9 m) installed at 13'(4 m), detection angle adjustable horizontally
Detectors
Logic Selector: And / Or
Sensitivity
Far: SH/H/M/L Near: SH/H/M/L Creep Zone: SH/H/M/L
Power Input
11 to 16 VDC, 22 to 26 VAC with heating unit (sold separately)
Current Draw
45 mA (maximum) at 12 VDC 80 mA (maximum) at 24 VAC 420 mA (maximum) at 24 VAC with heating unit (sold separately)
Alarm Period
Approximately 2 sec Interval Period: Off, 15, 30, 60 sec
Warm-Up Period
Approximately 60 sec
Alarm Output
Main Area (Far Area): N.O., N.C. 28 VDC 0.2 A (maximum) Main Area (Near Area): N.O., N.C. 28 VDC 0.2 A (maximum) Creep Zone: N.O., N.C. 28 VDC 0.2 A (maximum)
Mounting
Height: 7.6 to 13.0 ft/sec (2.3 to 4.0 m/sec)
Trouble Output
N.C 28 VDC, 0.2 A maximum
Tamper Output
N.C 28 VDC, 0.1 A maximum
Operating Temperature
-13 to 140°F, -40 to 140°F with heating unit (sold separately) (-25 to 60°C, -40 to 60°C with heating unit)
Weatherproof
Main Unit: IP65 Chasis: IP55
Dimensions
10.7 x 4.0 x 11.4" (271.0 x 102.0 x 290.0 mm)
Weight
3.5 lb (1.6 kg)
The user manual for the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100 can be downloaded in .pdf
format if it did not come with your new motion detectors, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Optex users keep a unique electronic library
for Optex motion detectorss,
where you can use our link to download the user manual for the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100.
The user manual lists all of the functions of the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100,
all the basic and advanced features and tells you how to use the motion detectors.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Optex service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100. User manuals are also
available on the Optex website under Surveillance - Alarm Systems - Motion Detectors.
Question and answer discussion forum concerning user instructions and resolving problems with the Optex REDWALL-V Series SIP-100 Outdoor Wired Synthesized SIP100
Why is the blue light (wireless symbol)...what is it on...its a blue light. I have had these for years and have never had that light come on and it is not allowing me to print! What do I do to turn it off? ...K&M manual - K&M 200 Telescoping Microphone Stand (Black) 20000-500-55 Posted by: jpdaval69 2024-09-10 00:50:11
I need the service manual/schematic of Universal Audio Solo/610 Serial number: 2310 MfgDt: 0607.
I hope you have it and I'm willing to be charged for it.
Best Regards....True Dock not recognizing hard drives - Kingwin True Dock Super-Speed USB 3.0 to TD-2535U3 Posted by: bf1955 2024-08-22 15:34:26
True Dock is not recognizing HDD, the HDD light does not come on, even though the power light does come one....