|
User manual for Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E
- Manufacturer: Q-Logic
- Basic description and contents of package
- Product classification: Computers & Solutions - Networking - Network Switches, Bridges & Hubs
- Safety instructions
- Startup and operation of the network switches, bridges & hubs
- Tips for setting up your Q-Logic
- Settings and expert assistance
- Contact Q-Logic service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E,
which address similar problems with connecting and setting up Network Switches, Bridges & Hubs Q-Logic.
|
User manual for the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E
The user manual for the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E provides
necessary instructions for the proper use of the product Computers & Solutions - Networking - Network Switches, Bridges & Hubs.
The Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel Switch is a single power unit including eight 8Gb SFP+ optics. This switch is manufactured by Q-Logic for EMC and is supported directly by EMC. It offers a simple and affordable way to share the capacity of Fiber Channel storage devices among multiple servers. The Q-Logic 3810 switch lets you maximize the value of your redundant array of independent disk (RAID) and tape library investments with simultaneous, direct-server connections through a state-of-the-art storage area network.
|
If you own a Q-Logic network switches, bridges & hubs and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E:
Fiber Channel Protocols | FC-AL Rev 4.6FC-AL-2 Rev 7.0 FC-DA FC-FLA FC-FS-2 FC-GS-5 FC-FG FC-LS FC-MI-2 FC-PH Rev. 4.3 FC-PH-2 FC-PH-3FC-PI-3FC-SP FC-Tape FC-VI FC-SW-4 Fiber channel element MIB RFC 2837Fiber alliance MIB version 4.0 | Fiber Channel Classes of Service | Classes 2 and 3 | Modes of Operation | Fiber channel classes 2 and 3, connectionless | Port Types | All ports are universal, auto-discovering and selfconfiguring, assuming the following states: F_Port, FL_Port, G_Port, GL_Port | Number of Fiber Channel Ports | 8x 8 Gb SFP ports | Maximum User Ports | > 475,000 ports depending on configuration | Buffer Credits | 16 buffer credits per port, ASIC embedded memory | Media Type | SFP and SFP+ optical transceivers | Fabric Port Speed | 1.0625, 2.125, 4.250 or 8.50 Gbps | Maximum Frame Size | 2148 bytes (2112 byte payload) | Supported SFP Types | Hot-pluggable, industry-standard, 3.3V SFP+ (8 Gb) transceivers Compatible with 4 Gb and 2 Gb SFPs Shortwave / longwave (optical), active copper | Maximum Media Transmission Ranges | At 2 Gbps: Shortwave optical: 1,640' (500 m) Longwave optical: 6.2 mi (10 km) | Cable Types | 50 / 62.5 micron multimode fiber optic9 micron single-mode fiber optic | System Processor | 400 MHz 440EP processor | Fabric Latency (intra-switch) | 2-Gbps to 2-Gbps: < 0.6 µsec 4-Gbps to 4-Gbps: < 0.3 µsec 8-Gbps to 8-Gbps: < 0.2 µsec | Fabric Point-to-Point Bandwidth | 425 Mb, full duplex @ 2-Gbps850 Mb, full duplex @ 4-Gbps | Aggregate(Single Switch) Bandwidth | 1700 Mb, full duplex @ 8-GbpsUp to 54.40 Gb full duplex | Operating Voltage | 100 to 240 VAC; 50 to 60 Hz | Power Source Loading | (maximum): 1 A at 120 VAC 0.5 A at 240 VAC | Heat Output | (maximum): 120 Watts | Circuit Protection | Internally fused | Diagnostics | Power-on self test (POST) tests all functional components except SFP transceivers Port tests include online, internal and external tests | User Interface | LED indicators | Management Methods | QuickTools web appletCommand line interfaceApplication programming interfaceSMI-SGS-3 management serverSNMPFTPTFTP | Connection | Maintenance Connection: RS-232 connector; null modem F / F DB9 cableEthernet Connection: RJ-45 connector; 10 / 100 BASE-T cable | Switch | Switch Agent: Allows a network management station to obtain configuration values, traffic information and failure data pertaining to the Fiber Channels using SNMP through the Ethernet interface. | Operating System | Windows 2003 and XP SP1/SP2 Solaris 9, 10 and 10 x86Red Hat enterprise Linux 4 and 5SUSE Linux enterprise server 9 and 10Mac OS x 10.4 and 10.5 | Memory | 512 Mb or more; 1 Gb recommended | Processor | 1 GHz or faster | Internet Browser | Microsoft Internet Explorer 6.0 or laterNetscape Navigator 6.0 and laterMozilla 1.5 and laterSafari 1.0 and later (on Mac OS) Firefox 1.5 and later | Software Requirements | Java 2 SE runtime environment 1.4.2 for QuickTools | Operating Temperature | 41 to 104° F (5 to 40° C) | Non-Operating Temperature | -4 to 158° F (-20 to 70° C) | Operating Humidity | 10 to 90%, non-condensing | Non-Operating Humidity | 10 to 95%, non-condensing | Operating Altitude | 0 to 10,000' (0 to 3048 m) | Non-Operating Altitude | 0 to 50,000' (0 to 15,240 m) | Operating Vibration | 5 - 500 Hz, 0.2 g, 3 axis, dwell | Non-Operating Vibration | 2 - 200 Hz, 0.6 g, 3 axis, dwell | Operating Shock | 4 g, 11 ms, half sine, 20 repetitions / axis | Non-Operating Shock | 30 g, 13 msec. 3 axis | Air Flow | Front-to-back | Mechanical Specifications | Optional rack-mount kitFront-to-back air patternRoHS compliant | Safety Standards | UL 60950 - 1 (USA)cUL 60950 - 1 (Canada) DEMKO and GS EN60950 - 1:2001, CE (Europe) CB Scheme: IEC 60950 - 1 (2001) GOST - R (Russia) | Emissions Standards | FCC part 15 Class AICES-003 issue 4VCCI Class A ITECISPR 22, Class AEN 55022, Class AAS / NZS CISPR 22 | Voltage Fluctuations | EN 61000 - 3 - 3 | Harmonics | EN 61000 - 3 - 2 | Immunity | EN 55024 | Marking | ULUS (United States)cUL (Canada)CE (Europe)UL / GS (Europe)DEMKO (Europe) | Dimension (DxWxH) | 19.69 x 17 x 1.7" (50 x 43.2 x 4.32 cm) | Weight | 13.5 lb (6.1 kg) | Package Weight | 18.9 lb | Box Dimensions (LxWxH) | 25.0 x 21.0 x 7.0" | |
The user manual for the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E can be downloaded in .pdf
format if it did not come with your new network switches, bridges & hubs, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Q-Logic users keep a unique electronic library
for Q-Logic network switches, bridges & hubss,
where you can use our link to download the user manual for the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E.
The user manual lists all of the functions of the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E,
all the basic and advanced features and tells you how to use the network switches, bridges & hubs.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Q-Logic service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E. User manuals are also
available on the Q-Logic website under Computers & Solutions - Networking - Network Switches, Bridges & Hubs.
Question and answer discussion forum concerning user instructions and resolving problems with the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Q-Logic SANbox 3810 8 Gbps 8-Port Fiber Channel SB3810-08A8-E
|
|
|
|
|