|
User manual for Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP
 Overall Rating: 4.5
90% of respondents would recommend this to a friend.
- Manufacturer: Sekonic
- Basic description and contents of package
- Product classification: Photography - Photo Accessories - Light Meters
- Safety instructions
- Startup and operation of the light meters
- Tips for setting up your Sekonic
- Settings and expert assistance
- Contact Sekonic service
- Troubleshooting
- Warranty information
- Price: 399 USD
|
We recommend checking out our discussion threads on the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP,
which address similar problems with connecting and setting up Light Meters Sekonic.
|
User manual for the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP
The user manual for the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP provides
necessary instructions for the proper use of the product Photography - Photo Accessories - Light Meters.
The Sekonic Litemaster Pro L-478D Light Meter and X-Rite ColorChecker Passport with Sekonic Gray Balance Card combines the innovative L-478D incident and flash meter with the ColorChecker Passport to simplify the process of calibrating your camera for accurate exposure levels and colors. Utilizing free software from Sekonic and X-Rite, photographers can easily create an exposure profile of their cameras, calibrate their meters and make profiles that will deliver optimal color and exposure settings for specific photo and cine applications.
|
If you own a Sekonic light meters and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP:
Metering Method | Incident light and reflected light (with optional attachment) | Receptor Head | Lumisphere convertible to flat diffuser (with retracted Lumisphere) | Receptor Element | Silicon photo diodes | Measuring Modes | Ambient: Aperture priority measuring, Shutter speed priority measuring, TF priority measuring, Cine measuring, HD Cine camera measuring, Illuminance measuring (lux, foot candle), Luminance measuring (foot-lambert, cd/m²) Flash: Cord Mode (with/without multiple cumulative), Cordless Mode (with/without multiple cumulative) | Measuring Range | Ambient- Incident: EV -2 to 22.9 (approx. f/2 at 15 sec. to f/22.9 at 1/8000 sec.) / Reflected: EV 3 to 19.9 Flash light- Incident: f/1.0 to f/128.9 / Reflected: f/2.8 to f/128.9 Illuminance- 0.63 to 2,000,000 lux / 0.10 to 180,000 fc (EV -2 to 19.6) Luminance (Reflected Light)- 1 to 980,000 cd/m² (EV 3 to 22.9) / 0.29 to 290,000 fl (EV 1.5 to 22.9) | Repeat Accuracy | +/- 0.1 EV or less | Calibration Constant | Incident: Lumisphere C = 340, Flat C = 250 Reflected: K = 12.5 | Power Source | 2x AAA dry cell batteries (alkaline, manganese, lithium, nickel hydride, or nickel-based) | Operating Temperature | 14-122°F / -10-50°C (no condensation) | Storage Temperature | -4-140°F / -20-60°C (no condensation) | Dimensions | 2.2 x 5.5 x 1" / 57 x 140 x 26 mm | Weight | 4.6 oz / 130 g (without batteries) | System Requirements | Windows: Microsoft Windows XP, Vista, or 7 (latest SP required, 32- and 64-bit versions supported) 512 MB RAM Intel Pentium 4 or AMD Athlon XP or better CPU 200 MB of available disk space Monitor resolution of 1024 x 768 or higher Internet connection required for software update
Macintosh Mac OSX 10.5.x, 10.6, 10.7, or 10.8 (with the latest updates installed) G4 Processor or higher (Intel recommended) 512 MB RAM 350 MB of available disk space Monitor resolution of 1024 x 768 or higher | Format | DNG | Compatible Software | Adobe Lightroom 2.0 or newer Adobe Photoshop Camera Raw 4.5 or newer Adobe Photoshop CS3 or newer Adobe Photoshop Elements 7 or newer Adobe Bridge CS3 or newer | Languages | English, French, Italian, German, Spanish, Portuguese, Simplified Chinese, Japanese | Dimension (D x W x H) | 4.9 x 3.5 x 0.4" (125 x 90 x 9 mm) | Weight | 3 oz (80 g) | Environmental Requirements | Temperature: 32-104°F (0-40°C) Humidity: 0-85% (non-condensing) | Package Weight | 1.1 lb | Box Dimensions (LxWxH) | 8.4 x 6.0 x 3.0" | |
The user manual for the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP can be downloaded in .pdf
format if it did not come with your new light meters, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Sekonic users keep a unique electronic library
for Sekonic light meterss,
where you can use our link to download the user manual for the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP.
The user manual lists all of the functions of the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP,
all the basic and advanced features and tells you how to use the light meters.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Sekonic service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP. User manuals are also
available on the Sekonic website under Photography - Photo Accessories - Light Meters.
Question and answer discussion forum concerning user instructions and resolving problems with the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the Sekonic Litemaster Pro L-478D Light Meter and X-Rite 401-478CCPP
|
|
|
|
|
Can't find what you're looking for? Try Google Search!
|
|
Current discussions |
Most recently discussed products:
Wiring/configure 501n-3 for rear view switch - Rear View Safety RVS-501N 3-Channel Multiplexer RVS-501N Posted by: Ron Diller 2025-05-06 23:25:57
Hello,I replaced the rv radio, which controls back,and turn signal cameras. How can I wire it to have the backup camera on all the time as a rear view mirror function, except when blinkers are on. Thanks! ... Wiring/configure 501n-3 for rear view switch - Rear View Safety RVS-501N 3-Channel Multiplexer RVS-501N Posted by: Ron Diller 2025-05-06 23:25:03
Hello,I replaced the rv radio, which controls back,and turn signal cameras. How can I wire it to have the backup camera on all the time as a rear view mirror function, except when blinkers are on. Thanks! ... sony alpha 7II - Sony Alpha a7 II Mirrorless Digital Camera with 28-70mm Lens Posted by: Clabue 2025-05-06 13:13:48
Alpha 7 II - Black + Sony FE 28-70mm f/3.5-5.6 OSS f/3.5-5.6
Where can I find a manual. It didn't come with the camera I just purchased online. Thank you.... FBA-Pioneer BDR-XU03 - Pioneer BDR-XU03 USB 3.0 BD/DVD/CD Burner BDR-XU03 Posted by: Mark Visel 2025-05-05 20:51:42
Sorry, but I am having one hell of a time finding this manual. Bought thru Amazon and am getting no where with finding manual. Can someone help.... SRD-92B setting - Fujinon SRD92B Zoom Rate Demand SRD-92B Posted by: Matthew Allen 2025-05-04 14:10:30
How can we make the speed adjustment control slower... |
|