|
User manual for SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000
- Manufacturer: SURGEX
- Basic description and contents of package
- Product classification: Computers & Solutions - Power - UPS Backup
- Safety instructions
- Startup and operation of the ups backup
- Tips for setting up your SURGEX
- Settings and expert assistance
- Contact SURGEX service
- Troubleshooting
- Warranty information
|
We recommend checking out our discussion threads on the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000,
which address similar problems with connecting and setting up UPS Backup SURGEX.
|
User manual for the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000
The user manual for the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000 provides
necessary instructions for the proper use of the product Computers & Solutions - Power - UPS Backup.
The Stand-Alone Online Battery Backup/Surge Eliminator & Power Conditioner from SurgeX is a bundled product that combines a UPS and a surge eliminator. This combination is ideal for sensitive audio-video systems, critical business servers, point-of-sale equipment, telephones, and data network equipment that demand prolonged runtimes. The battery backup keeps the equipment running and properly shuts down critical systems in the event of a power outage. For critical systems that require online battery backup, it delivers network-grade power through double-conversion technology. It provides extended scalable runtimes of up to 18 hours, via optional self-charging extended battery packs and replaceable battery trays.
|
If you own a SURGEX ups backup and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000 in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000:
Interface | 3U | Capacity | 2000 VA (1400 W) | Voltage | 120 VAC (80 to 138 V at 100% load and 60 to 138 V at 40% load) | Frequency | 50/60 Hz (autosensing) | Line Cord | 5-20P | Receptacles | 1 x NEMA L5 - 20R + 4 x NEMA 5 - 20R | Wave Form | Sine wave, zero transfer time | Load Power Factor | 0.7 | Efficiency AC/DC/AC | ≥ 90% | Power Factor | ≥ 0.97 | Topology | True online, double conversion, input power factor correction | Auto Restart | Yes | Start on Battery | Yes | Battery Type (UPS) | 4 x 12 V, 7.2 AH/48 V | Backup Time | 7 to 11 minutes (internal batteries) to 18 hours using External Battery Packs (EBP) | Extended Battery Packs | EBP2 | Battery Type (EBP) | 2 x Strings of 4 x 12 V, 7.2 AH/48 V | Audible Alarm | Beeps in every 4 seconds (when working on the battery) | LCD Visual Display | Input/output voltage and frequency, online mode, back-up mode, battery capacity, and load level | Recharge Time | Typical: < 4 hours | Rated Current | 16.6 A | Overload Capacity | 110 to 150% for 30 seconds ≥ 150% for 200 milliseconds | Crest Factor | 3:1 at full load | Audible Noise | < 50 dB (A) at 3.2' (1.0 m) | Operating Temperature | 32 to 104°F (0 to 40°C) | Altitude | 6000.0' (1828.8 m) above sea level | Certifications | UL, cUL, and FCC | Dimensions | 17.3 x 21.7 x 5.2" (43.9 x 55.1 x 13.2 cm) | Weight | 79.4 lb (36.0 kg) | Load Rating | 20 A at 120 V | Power Requirement | 15 W at no load | Certifications & Approvals | UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured Suppressed Voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 ohms load): 40 dB at 100 kHz, 50 dB at 300 kHz, 50 dB at 3 MHz, 50 dB at 30 MHz EMI/RFI Filter, Common Mode (50 ohms load): 18 dB at 300 kHz, 30 dB at 1 MHz, 50 dB at 5 MHz, 50 dB at 20 MHz | Safety | Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000 Undervoltage Shutdown: 90 V (resume at 100 V) Overvoltage Shutdown: 145 V (resume at 135 V) Maximum Load Inrush Current During Power-up: 1,000 Joules 1 | Temperature Range | 41 to 95°F (5 to 35°C) | Relay Contact Rating | Auxiliary: 30 V at 1 A | LED Output | 12 VDC, maximum 20 mA (resistor required) | Humidity Range | 5 to 95% RH (non-condensing) | |
The user manual for the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000 can be downloaded in .pdf
format if it did not come with your new ups backup, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other SURGEX users keep a unique electronic library
for SURGEX ups backups,
where you can use our link to download the user manual for the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000.
The user manual lists all of the functions of the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000,
all the basic and advanced features and tells you how to use the ups backup.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from SURGEX service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000. User manuals are also
available on the SURGEX website under Computers & Solutions - Power - UPS Backup.
Question and answer discussion forum concerning user instructions and resolving problems with the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000 - no comments have been made yet - be the first to add a comment
Post new comment/question/response regarding the SURGEX Stand-Alone Online Battery Backup/Surge SXBDLUPS2000
|
|
|
|
|
Can't find what you're looking for? Try Google Search!
|
|
Current discussions |
Most recently discussed products:
Wiring/configure 501n-3 for rear view switch - Rear View Safety RVS-501N 3-Channel Multiplexer RVS-501N Posted by: Ron Diller 2025-05-06 23:25:57
Hello,I replaced the rv radio, which controls back,and turn signal cameras. How can I wire it to have the backup camera on all the time as a rear view mirror function, except when blinkers are on. Thanks! ... Wiring/configure 501n-3 for rear view switch - Rear View Safety RVS-501N 3-Channel Multiplexer RVS-501N Posted by: Ron Diller 2025-05-06 23:25:03
Hello,I replaced the rv radio, which controls back,and turn signal cameras. How can I wire it to have the backup camera on all the time as a rear view mirror function, except when blinkers are on. Thanks! ... sony alpha 7II - Sony Alpha a7 II Mirrorless Digital Camera with 28-70mm Lens Posted by: Clabue 2025-05-06 13:13:48
Alpha 7 II - Black + Sony FE 28-70mm f/3.5-5.6 OSS f/3.5-5.6
Where can I find a manual. It didn't come with the camera I just purchased online. Thank you.... FBA-Pioneer BDR-XU03 - Pioneer BDR-XU03 USB 3.0 BD/DVD/CD Burner BDR-XU03 Posted by: Mark Visel 2025-05-05 20:51:42
Sorry, but I am having one hell of a time finding this manual. Bought thru Amazon and am getting no where with finding manual. Can someone help.... SRD-92B setting - Fujinon SRD92B Zoom Rate Demand SRD-92B Posted by: Matthew Allen 2025-05-04 14:10:30
How can we make the speed adjustment control slower... |
|