User manual SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT
Operating instructions and pdf manual for use - SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT User manual, User manual SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT, SURGEX, SX20, NE/RT, Surge, Eliminator, Power, SX20NERT,
User manual for SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT
Manufacturer: SURGEX
Basic description and contents of package
Product classification: Pro Audio - Power Equipment - Power Distributors & Conditioners
Safety instructions
Startup and operation of the power distributors & conditioners
Tips for setting up your SURGEX
Settings and expert assistance
Contact SURGEX service
Troubleshooting
Warranty information
Price: 599 USD
We recommend checking out our discussion threads on the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT,
which address similar problems with connecting and setting up Power Distributors & Conditioners SURGEX.
User manual for the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT
The user manual for the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT provides
necessary instructions for the proper use of the product Pro Audio - Power Equipment - Power Distributors & Conditioners.
The SurgeX SX20 NE/RT Surge Eliminator & Power Conditioner has remote control capability for use in AC power distribution systems and can be interfaced with a sequential controller such as the SurgeX SEQ. The unit can be controlled with an applied voltage between 5 and 30VDC or a contact closure switch connected to the Phoenix connector terminal block. The connector can also be used to cascade multiple units or provide status to a central controller.
If you own a SURGEX power distributors & conditioners and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT in the following formats:
*.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT:
Load Rating
20 A @ 120 V
Power Requirement
15 W @ no load
Certifications & Approvals
UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse and measured suppressed voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 Ω load): 40 dB at 100 kHz, 50 dB at 300 kHz, 50 dB at 3 MHz, 50 dB at 30 MHz EMI/RFI Filter, Common Mode (50 Ω load): 18 dB at 300 kHz, 30 dB at 1 MHz, 50 dB at 5 MHz, 50 dB at 20 MHz
Safety
Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1000 Under-Voltage Shutdown: 90 V (resume at 100 V) Over-Voltage Shutdown: 145 V (resume at 135 V) Maximum Load Inrush Current During Power-Up: 1,000 Joules
1.2 x 50 µs pulse, industry standard combination wave surge, as per IEEE C62.41.
Remote
Remote Turn-on Applied Voltage Range: 5 to 30 VDC Remote Turn-on Current Draw: 3 mA @ contact closure, 1 mA @ 5 VDC applied voltage, 2.5 mA @ 12 VDC applied voltage, 5 mA @ 24 VDC applied voltage
The user manual for the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT can be downloaded in .pdf
format if it did not come with your new power distributors & conditioners, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other SURGEX users keep a unique electronic library
for SURGEX power distributors & conditionerss,
where you can use our link to download the user manual for the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT.
The user manual lists all of the functions of the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT,
all the basic and advanced features and tells you how to use the power distributors & conditioners.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from SURGEX service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT. User manuals are also
available on the SURGEX website under Pro Audio - Power Equipment - Power Distributors & Conditioners.
Question and answer discussion forum concerning user instructions and resolving problems with the SURGEX SX20 NE/RT Surge Eliminator & Power SX20NERT - no comments have been made yet - be the first to add a comment
Why is the blue light (wireless symbol)...what is it on...its a blue light. I have had these for years and have never had that light come on and it is not allowing me to print! What do I do to turn it off? ...K&M manual - K&M 200 Telescoping Microphone Stand (Black) 20000-500-55 Posted by: jpdaval69 2024-09-10 00:50:11
I need the service manual/schematic of Universal Audio Solo/610 Serial number: 2310 MfgDt: 0607.
I hope you have it and I'm willing to be charged for it.
Best Regards....True Dock not recognizing hard drives - Kingwin True Dock Super-Speed USB 3.0 to TD-2535U3 Posted by: bf1955 2024-08-22 15:34:26
True Dock is not recognizing HDD, the HDD light does not come on, even though the power light does come one....