  • Manufacturer: Tektronix
  • Basic description and contents of package
  • Product classification: Professional Video - Signal Processing & Distribution - Video & Audio Signal Generators
  • Safety instructions
  • Startup and operation of the video & audio signal generators
  • Tips for setting up your Tektronix
  • Settings and expert assistance
  • Contact Tektronix service
  • Troubleshooting
  • Warranty information
Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000 Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000
Click to enlarge image

We recommend checking out our discussion threads on the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000, which address similar problems with connecting and setting up Video & Audio Signal Generators Tektronix.



User manual for the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000

The user manual for the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000 provides necessary instructions for the proper use of the product Professional Video - Signal Processing & Distribution - Video & Audio Signal Generators.

The Tektronix ECO8000 Automatic Changeover Basic Unit is a versatile automatic sync and signal changeover unit with configurations and capabilities required to address modern master sync application and other advanced sync timing application. It supports optional high bandwidth input changeover capabilities for HD/SD-SDI and/or 3G-SDI signal environments. It can be used with the following optional signal generators to form the complete sync generator system, which offers extra redundancy for the critical timing and synchronization system in the facilities:

- A pair of Tektronix Master Sync / Master Clock Reference Generators (model # SPG8000) for most broadcast facility timing applications.

- A pair of Tektronix Test Signal Generators (model # TG8000) for more advanced post production facility timing applications.

The ECO8000 features 9 switchable BNC channels, each consisting of primary and backup inputs and an output.
If you own a Tektronix video & audio signal generators and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000 in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000:
Specifications
    Channels 9 x switchable BNC channels (primary and backup)
    Typical Return Loss Base and Option REF 50 MHz Electronic Fast Switch Channels:
    35 dB, 300 kHz to 6 MHz
    25 dB, 6 MHz to 30 MHz

    Option HREF 3 GHz Relay Switch Channels:
    40 dB, 300 kHz to 6 MHz
    30 dB, 6 MHz to 30 MHz
    15 dB, 30 MHz to 1.5 GHz
    10 dB, 1.5 GHz to 3 GHz
    Insertion Loss Base and Option REF 50 MHz Electronic Fast Switch Channels:
    < ±0.2 dB DC to 10 MHz
    Typical < -1 dB DC to 50 MHz

    Option HREF 3 GHz Relay Switch Channels:
    < -0.1 dB DC to 10 MHz
    Typical < -3 dB DC to 3 GHz
    Equivalent to approx. 16 ft (5 m) of Belden 1694 cable
    Maximum Switched Voltage Base and Option REF 50 MHz Electronic Fast Switch Channels:
    -3 to 5 V

    Option HREF 3 GHz Relay Switch Channels:
    ±2.5 V peak, 1.5 V RMS

    Option LTC Channels:
    ±5 V
    Maximum Switched Current (Option HREF only): 100 mA
    Crosstalk Base and Option REF 50 MHz Electronic Fast Switch Channels:
    < -60 dB, 300 kHz to 6 MHz
    < -40 dB, 6 MHz to 50 MHz

    Option HREF 3 GHz Relay Switch Channels:
    < -48 dB, DC to 1.5 GHz
    < -40 dB, 1.5 GHz to 3 GHz
    Relay Switch Interruption Time (Option HREF only):

    Time for Relays to Switch and Settle:
    Typically 0.5 ms to 2 ms
    Channel Switch Settling Time (Base and Option REF only with identical signals on both inputs):

    Time for Relays to Switch and Settle:

    Bi-Level and Tri-Level Sync:
    Typically 5 ns glitch, then 125 ns to 90% of final value
    AES and 1 V Word Clock:
    Typically 5 ns glitch, then 250 ns to 90% of final value
    5 V Word Clock:
    Typically 25 ns glitch, then 500 ns to 90% of final value
    Preset Threshold Signal Types Base and Option REF 50 MHz Electronic Fast Switch Channels:
    NTSC, PAL, Tri-level, AES, 1 V word clock, 5 V word clock, custom

    Option HREF 3 GHz Relay Switch Channels:
    NTSC, PAL, Tri-level, AES, 1 V word clock, SD-SDI, HD-SDI, 3G-SDI, custom
    Signal Level Range to Detect Fault With preset thresholds:
    -2 dB to -4 dB from the nominal level for the selected signal type
    LTC Channels LTC Threshold Presets:
    0.5 to 5 Vp-p in 0.5 V steps, differential or single ended

    LTC Load Range:
    600 Ω to open circuit

    Crosstalk:
    < -60 dB for LTC signals

    Switching Interruption Duration:
    Typically 1 ms
    Power Source Mains Ranges:

    Voltage: 100 to 240 VAC
    Frequency: 50/60 Hz
    Power Consumption: 50 VA maximum
    Operating Temperature +32 to 122°F (0 to 50°C)
    Storage Temperature -4 to 140°F (-20 to 60°C)
    Operating Altitude To 9842 ft (3000 m)
    Regulatory EMC:
    Complies with EMC Directive 2004/108/EC

    Safety:
    Approved to: UL61010-1, CAN/CSA-C22.2 No.61010-1
    Complies with: EN61010-1, IEC61010-1
    Dimensions 1.7 x 19 x 22" (4 x 48 x 56 cm)
    Weight 10 lb (4.5 kg)
    The user manual for the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000 can be downloaded in .pdf format if it did not come with your new video & audio signal generators, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other Tektronix users keep a unique electronic library for Tektronix video & audio signal generatorss, where you can use our link to download the user manual for the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000.

    The user manual lists all of the functions of the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000, all the basic and advanced features and tells you how to use the video & audio signal generators. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from Tektronix service.

    If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000. User manuals are also available on the Tektronix website under Professional Video - Signal Processing & Distribution - Video & Audio Signal Generators.



    Discussion Question and answer discussion forum concerning user instructions and resolving problems with the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000 - no comments have been made yet - be the first to add a comment

    Post new comment/question/response regarding the Tektronix ECO8000 Automatic Changeover Basic Unit ECO8000

    Fields marked with * must be filled out.
    Your name *:
    E-mail :
    Subject *:
    Message text *:
    Enter the code *:
    (spam block)
    "manual"
    If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

     

    Can't find what you're looking for? Try Google Search!



    Current discussions
    Most recently discussed products:

    Swarm MX100 manual - Wildgame Innovations MX100E Swarm Series Digital Metal MX100E
    Posted by: Ananya
    2024-05-07 01:03:29

    Here is the manual for MX100 but you can't download it. https://drive.google.com/file/d/1-tHQFDDHom3F41MiA8a9avebXZ2vdbHN/view?usp=sharing...
    User Manual online - Wildgame Innovations MX100E Swarm Series Digital Metal MX100E
    Posted by: Ananya
    2024-05-07 00:57:44

    Here is the manual for MX100 but you can't download it. https://issuu.com/jknotek/docs/mx100-manual...
    Lost LCO manual - Leupold 1x32 LCO Reflex Sight (1 MOA Red Dot Reticle) 119691
    Posted by: J.B. Seemore
    2024-05-05 03:20:24

    Please share the. pdf manual for your LCO Red dot. Love your optics JB Seemore ...
    User Manual - Celluon evoMouse EVOMOUSE
    Posted by: Darlington Amadi
    2024-05-02 13:51:35

    Hello Please need a manual for this device Celluon, Inc.(Model:evoMouse) Input: 5V 0.5A Class 1M Laser: IEC-60825-1 KC NO: MSIP-REM-CLK-EVO S/N: E140234231 ...
    manual - Fujinon XT17sx45BRMK1 17x 4.5mm HD ENG Lens XT17SX4.5BRM
    Posted by: dinohacket
    2024-05-01 17:18:07

    manual...

    Uploaded instruction manuals
    Upload a link to an instruction manual for a depicted product here:

    Link format "http://www.link2manual.com/manual.pdf"

    Enter the code: "manual"






    PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
    sitemap.txt alx