X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA
  • Manufacturer: X-Rite
  • Basic description and contents of package
  • Product classification: Computers & Solutions - Monitor & Display Accessories - Calibration
  • Safety instructions
  • Startup and operation of the calibration
  • Tips for setting up your X-Rite
  • Settings and expert assistance
  • Contact X-Rite service
  • Troubleshooting
  • Warranty information
We recommend checking out our discussion threads on the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA, which address similar problems with connecting and setting up Calibration X-Rite.



User manual for the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA

The user manual for the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA provides necessary instructions for the proper use of the product Computers & Solutions - Monitor & Display Accessories - Calibration.

The i1Publish Pro 2 Software (Upgrade A) from X-Rite is a software suite with an upgrade solution for ultimate, professional level color management. It includes the i1Profiler v1.x, ColorChecker Camera Calibration, PANTONE Color Manager, ColorChecker Classic target [mini] and ColorChecker Proof target softwares. Its reliability, versatility and accurate color calibrating software helps save time, ink, paper and provides all the functionalities featured in i1Publish Pro 2 solution. The upgrade package includes i1Basic Pro 2 and i1Publish Software Upgrade.
To be eligible for this upgrade you must own one of the following:
i1Basic, i1Design LT or i1Photo LT with any additional i1Match module added, i1Photo, i1Photo SG, i1Photo Pro, i1Proof, i1XT,i1Xtreme, ProfileMaker 5*, MonacoPROFILER 4*
If you originally purchased i1Photo, i1Photo SG, i1Proof, i1xt or i1xtreme - buy i1Publish Upgrade A to get full i1Publish Pro functionality. All profilemaker 5 packages are eligible for the upgrade - purchase i1Publish Pro 2 Upgrade A (Use your existing Hasp4 dongles, still keep your license flags for profilemaker 5 software and receive all the new software, hardware and components.)
If you own a X-Rite calibration and have a user manual in electronic form, you can upload it to this website using the link on the right side of the screen.

You can upload and download the manual for the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA in the following formats:
  • *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
Additional parameters of the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA:
Hardware Spectral engine: i1 technology with built-in wavelengths check
Spectral analyzer: Holographic diffraction grating with 128-pixel diode array
Spectral Range: 380 - 730 nm
Physical sampling interval: 3.5 nm
Optical resolution: 10 nm
Spectral reporting: 380 to 730 nm in 10 nm steps
Measurement Frequency in scanning mode: 200 measurements per second
Interface USB 1.1
Power Supply Device powered by USB. No additional charger or battery required
Optics Measurement geometry: 45°/0° ring illumination optics, ISO 13655:2009
Measurement aperture: 0.18" (4.5 mm) diameter (effective measurement aperture during scanning is dependent on the patch size and measurement speed)
Illumination Spot Size: 0.14" (3.5 mm)
Light source: Gas-filled tungsten (illuminant type A) and UV LED
Data Format Spectral Reflectance [dimensionless]
Measurement UV included - ISO 13655:2009 measurement condition M0
D50 - ISO 13655:2009 measurement condition M1
UV excluded Filter - ISO 13655:2009 measurement condition M2
OBC: Optical Brightener Compensation (OBC) with i1Profiler software
Calibration: Manual on external ceramic white reference
Measurement Background: white, ISO 13655:2009; for measurements on backup board
Maximum Media Thickness: 0.12" (3 mm) on backup board
Minimum Patch Size in Scanning Mode: 0.28 x 0.39" (7 x 10 mm) (Width x Height) with sensor ruler
0.39 x 0.39" (10 x 10 mm) (Width x Height) without sensor ruler
Inter-instrument agreement: 0.4 ∆E94* average, 1.0 ∆E94* max.
Short-term repeatability: 0.1 ∆E94** on white

*deviation from X-Rite manufacturing standard at a temperature of 73.4ºF on 12 BCRA tiles (D50, 2º)
**D50, 2°, mean of 10 measurements every 3 secs on white

Emissions Data format: Spectral radiance (mW/nm/m2 /sr); Luminance Y (cd/m2)
Measurement range: 0.2 - 1200 cd/m2 on a typical LCD-Monitor
Short-term repeatability: x,y: +/- 0.002 typical (5000°K, 80 cd/m2)
Ambient Modes Data Format: spectral irradiance [mW/nm/m2], illuminance [lux]
Type: Cosine-corrected diffuse light measurement head
Operating Temperature 50 to 95°F (10 to 35°C)
Operating Humidity 0% to 80% non-condensing
System Requirements Macintosh
Mac OS X 10.6.x, 10.7.x and 10.8x
(with the latest updates installed)
1GB RAM
Intel Processor
Up to 2GB of available disk space (depending on components installed)
Powered USB Port
Monitor resolution of 1024x768 pixels or higher Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
DVD drive or high-speed internet connection required for software installation, download and automatic software update

Windows
Microsoft Windows: XP 32 bit, Vista 32 or 64 bit, Windows 7 32 or 64 bit, Windows 8 32 or 64 bit
(with latest service pack installed)
1GB RAM
Intel Pentium IV or AMD Athlon XP or better CPU
Up to 2GB of available disk space (depending on components installed)
Powered USB Port
Monitor resolution of 1024x768 pixels or higher
Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
Network adaptor installed and driver loaded
DVD drive or high-speed internet connection required for software installation, download and automatic software update

Languages Chinese (Simplified), English, French, German, Italian, Japanese, Portuguese, Spanish, Russian
Physical Dimensions i1Pro device (L x W x H): 6.1 x 2.6 x 2.6" (155 x 66 x 67 mm)
i1 Ruler (L x W): 13.3 x 4.0" (337 x102 mm)
i1 Backup Board: 14.0 x 10.4" (355 x 265 mm) folded/ 14.0 x 15.7" (355 x 400 mm) unfolded
Weight i1Pro device: 8.6 oz (245 g)
Packaging Info
Package Weight 9.8 lb
Box Dimensions (LxWxH) 17.0 x 14.0 x 6.0"
The user manual for the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA can be downloaded in .pdf format if it did not come with your new calibration, although the seller is required to supply one. It is also quite common that customers throw out the user manual with the box, or put the CD away somewhere and then can’t find it. That’s why we and other X-Rite users keep a unique electronic library for X-Rite calibrations, where you can use our link to download the user manual for the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA.

The user manual lists all of the functions of the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA, all the basic and advanced features and tells you how to use the calibration. The manual also provides troubleshooting for common problems. Even greater detail is provided by the service manual, which is not typically shipped with the product, but which can often be downloaded from X-Rite service.

If you want to help expand our database, you can upload a link to this website to download a user manual or service manual, ideally in .pdf format. These pages are created by you – users of the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA. User manuals are also available on the X-Rite website under Computers & Solutions - Monitor & Display Accessories - Calibration.



Discussion Question and answer discussion forum concerning user instructions and resolving problems with the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA - no comments have been made yet - be the first to add a comment

Post new comment/question/response regarding the X-Rite i1Publish Pro 2 Software (Upgrade A) EO2BAS-UPGA

Fields marked with * must be filled out.
Your name *:
E-mail :
Subject *:
Message text *:
Enter the code *:
(spam block)
"manual"
If you would like to receive a response to your comment, don’t forget to include your e-mail address. Your e-mail will not be displayed or otherwise used in any way.

 

Can't find what you're looking for? Try Google Search!



Current discussions
Most recently discussed products:

Simmons 6-24x50 - Simmons 6-24x50 Predator Varmint Riflescope 656245
Posted by: Stuart Williams
2024-03-26 12:36:48

I have located manual for this on your site but how do I download / print it please ?...
USER MANUAL TSP2 17 BUN - Telmax TSP2-17-BUN Dual 17" Presidential TSP2-17BUN
Posted by: AYO
2024-03-26 10:07:35

MANUAL REQUIRED TO SET UP...
lens servo - Fujinon ESM-15A-SA Digital Servo Unit for Fujinon ESM-15A-SA
Posted by: julia yoko
2024-03-25 22:07:20

i would like to know where the lens manual can be found...
NEPVS14-17 - ITT Night Enforcer PVS-14 Pinnacle Night Vision ITTE-NEPVS14-17
Posted by: Keller Bradshaw
2024-03-25 17:57:35

Hi, I would like a user manual for the NEPVS14-17...
YS 03 above water - Sea & Sea YS-03 Universal Lighting System SS-03541
Posted by: sameer
2024-03-24 22:26:52

Hello Would like to know is it safe to use YS 03 strobe outside water for practice purpose ? Regards...

Uploaded instruction manuals
Upload a link to an instruction manual for a depicted product here:

Link format "http://www.link2manual.com/manual.pdf"

Enter the code: "manual"






PDF-MANUALS.com - Community administered database of instructions for use and PDF User manual
sitemap.txt alx